User Manual

Remote Control Commands
R&S
®
Scope Rider RTH
373User Manual 1326.1578.02 ─ 08
Return values:
<Enabled> ON | OFF
*RST: OFF
Usage: Query only
LOGGer:MEASurement<m>:TYPE?
Returns the measurement type of the selected measurement.
Suffix:
<m>
.
1..4
Return values:
<Type> See MEASurement<m>:TYPE on page 288.
Usage: Query only
LOGGer:MEASurement<m>:SOURce?
Returns the source channel of the selected measurement.
Suffix:
<m>
.
1..4
Return values:
<Source> C1 | C2 | C3 | C4 | M1 | R1 | XY | D0 | D1 | D2 | D3 | D4 | D5 |
D6 | D7
<Source2> C1 | C2 | C3 | C4 | M1 | R1 | XY | D0 | D1 | D2 | D3 | D4 | D5 |
D6 | D7
Example:
LOGGer:MEASurement4:SOURce?
<-- C2,C1
Measurement 4 is a delay measurement on source 1 = C2 and
source 2 = C1
Usage: Query only
14.10.5 Logger Records
You can export the data of an active slot to a file, in CSV or MAT format. See also:
Chapter 7.6, "Logger Records", on page 156.
LOGGer:SLOT:ACTive?................................................................................................. 373
LOGGer:SLOT:EXPort:NAME......................................................................................... 374
LOGGer:SLOT:EXPort:SAVE..........................................................................................374
LOGGer:SLOT:ACTive?
Returns the active slot. The active slot is the slot where logger data is stored, and the
data is loaded for display.
Data Logging