Suffix:
<m>
.
*
Selects the word.
Return values:
<StopTime> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
BUS:UART:WORD<m>:VALue?
Return the value of the specified symbol (word).
Suffix:
<m>
.
*
Selects the word.
Return values:
<Value> Decimal value
Range: 0 to 255
Increment: 1
*RST: 0
Usage: Query only
14.11.5 CAN (Option R&S RTH-K3)
● CAN Configuration Settings.................................................................................. 399
● CAN Trigger.......................................................................................................... 402
● CAN Decode Results............................................................................................ 405
14.11.5.1 CAN Configuration Settings
BUS:CAN:DATA:SOURce...............................................................................................399
BUS:CAN:TYPE............................................................................................................ 400
BUS:CAN:BITRate......................................................................................................... 400
BUS:CAN:TECHnology...................................................................................................401
BUS:CAN:DATA:THReshold........................................................................................... 401
BUS:SETReflevels......................................................................................................... 401
BUS:CAN:SAMPlepoint.................................................................................................. 401
BUS:CAN:DATA:SOURce <Channel>
Sets the input channel of the CAN line.