Setup Manual
Table Of Contents
- R&S®Tx9 Transmitter System
- Contents
- 1 Information about this Manual
- 3 Introduction to Operation
- 4 Device View Description
- 4.1 System Overview
- 4.2 Transmitter
- 4.3 Exciter DVB-T2
- 4.6 Exciter ATSC
- 4.7 Exciter DTMB
- 4.11 Switchless Combiner
- 4.12 Cooling System
- 5 Task View Description
- 6 Operating the Device Manager
- 7 User Administration
Task View Description
R&S
®
Tx9
231Operating Manual 2109.9110.02 ─ 07
Fig. 5-2: SNMP manager settings
Being able to monitor and control a transmitter with SNMP requires the device's MIB
on the manager end and a program that can interpret the MIB. You can load all availa-
ble MIBs from any device using a web browser.
●
Log in using the WebGUI and select the menu Task View > System Control >
Downloads > Download SNMP MIBs
●
Save the mibs.zip file to your computer
●
Load the following MIBs in the MIB browser:
–
RS-COMMON-MIB
– RS-XX9-SMI-MIB and RS-XX9-TC-MIB
– RS-XX9-COMMON-MIB
– MIB of the standby concept, standard or option
A detailed description of the MIBs, the information that they contain and the associated
options is given below.
MIBs from Rohde & Schwarz and the Munich-based Broadcast Technology Institute
(IRT) are available. MIBs from IRT allow transmitters to be linked using SNMP irre-
spective of the manufacturer. They are, however, limited with respect to their function-
ality. Some particular features to keep in mind when using IRT MIBs are listed in the
document "SoftwareMiniSpecification – SNMP for XX9".
The MIBs have the naming convention RS-XX9-<TV/radio standard>-<function/
option>-MIB. Examples include: RS-XX9-DVBT2-MIB for DVB-T2 and RS-XX9-AIR-
COOLING-MIB for air cooling.
System Control