Setup Manual

Table Of Contents
Task View Description
R&S
®
Tx9
233Operating Manual 2109.9110.02 ─ 07
MIB Description
RS-COMMON-MIB This MIB contains general Rohde & Schwarz definitions.
RS-XX9-AIR-COOLING-MIB This MIB contains parameters for air-cooled transmitters.
RS-XX9-COMMON-MIB This MIB contains general data that supports every device:
Transmitter configuration
Option keys
Software update
SNMP configuration
Releasing a test notification
This information always applies to the device using SNMP.
RS-XX9-LIQUID-COOLING-MIB This MIB contains parameters for liquid-cooled transmitters, either
with internal Rohde & Schwarz cooling or with (external) station cool-
ing.
RS-XX9-MTX-MIB This MIB contains parameters independent of the type of modulation
for:
MultiTx
N+1
RS-XX9-SMI-MIB This MIB contains top-level definitions of other XX9 MIBs.
RS-XX9-TC-MIB This MIB contains definitions for textual conventions used in other
MIBs.
RS-XX9-TX-MIB This MIB contains parameters independent of the type of modulation
for:
Single drive standby concepts
Passive dual drive
Active dual output stage
This applies to all power classes in the medium- and high-power
range.
RS-XX9-ATSC-MIB This MIB contains parameters for ATSC signal processing.
RS-XX9-ATV-MIB This MIB contains parameters for ATV signal processing.
RS-XX9-DAB-MIB This MIB contains parameters for DAB signal processing.
RS-XX9-DTMB-MIB This MIB contains parameters for DTMB signal processing.
RS-XX9-DVBT-MIB This MIB contains parameters for DVBT signal processing.
RS-XX9-DVBT2-MIB This MIB contains parameters for DVBT2 signal processing.
RS-XX9-FM-MIB This MIB contains parameters for FM signal processing.
RS-XX9-ISDBT-MIB This MIB contains parameters for ISDBT signal processing.
5.3.1.5 Which OIDs from a MIB Must Be Used?
Different parameters are available depending on the system being queried. For exam-
ple, txExcAutoOperationMode (in RS-XX9-TX-MIB) returns the response NoSuch-
Name when you query a single transmitter, since it has no automatic exciter switch-
over. It is easy to find out which parameters are valid by checking the conformance
statements. In the example for automatic exciter switchover above, the OID txExcAu-
toOperationMode is contained in the txObjsExciterAutomatic object group.
System Control