Setup Manual

Table Of Contents
Task View Description
R&S
®
Tx9
219Operating Manual 2109.9110.02 ─ 07
5 Task View Description
5.1 Basic Settings
The structure of the transmitter system is configured in the "Basic Setup" menu. Each
R&S TCE900 is assigned its logical function together with the other R&S TCE900
units, the physical installation position of the individual R&S TCE900 units is set and
the distribution of transmitters and R&S TCE900 units in the racks is described.
The basic settings are made for each R&S TCE900 in the system and must be entered
in the specified sequence:
Hardware equipment ("Boards" menu tab)
The hardware modules which each R&S TCE900 contains and at which position
these modules are inserted in the R&S TCE900 base unit must be configured for
each R&S TCE900.
Definition of the logical function
The task that each R&S TCE900 is to fulfill in the system must be defined.
Integration of the R&S TCE900 in the transmitter system
Depending on their function, some R&S TCE900 units require additional informa-
tion regarding:
system variant (MultiTX, N+1)
transmitter variant (Redundancy, Modulation, Amplifier Type)
assignment to a transmitter (TX Number, Exciter A/B)
Physical structure of the transmitter system
Depending on their function, some R&S TCE900 units require additional informa-
tion regarding:
total number of transmitter racks
number of racks per transmitter
Physical installation location of the R&S TCE900 units
Each R&S TCE900 must be assigned the following:
number of the rack in which the R&S TCE900 is installed
number of the installation slot within a rack
Assignment of transmitters to racks ("Racks" menu tab)
Each R&S TCE900 with the "Rack Control" function must be assigned those trans-
mitters which are installed in the racks that the "Rack Control" function monitors.
Changes to the basic settings only become effective when the R&S TCE900 has been
restarted.
In the tables below, "?" means that it must be taken into consideration whether an air
cooling interface (ACIF) or a TX interface is installed. See the detailed description of
the "Cooling Control" and "Rack Control" parameters in the table "Description of set-
ting values".
Basic Settings