Table 5-9: IP addresses for N+1 systems (<n> = 1 to 8; TXB <n> = 9; <m> = 2 to 9, No. of Rack Con-
trols)
Transmitter type Ethernet Local
Single drive
System Control 192.168.58.100
Exciter (TX A<n>, TX B) 192.168.58.<n>1
Rack Control (where applicable) 192.168.58.10<m>
Dual drive
System Control 192.168.58.100
Exciter A (TX A<n>, TX B) 192.168.58.<n>1
Exciter B (TX A<n>, TX B) 192.168.58.<n>2
Rack Control (where applicable) 192.168.58.10<m>
Table 5-10: Description of setting values
Name Description Value range Access right
System Con-
trol
Set this check mark if this cassette of the R&S TCE900 is
to function as a system control unit. In this case, all
remote control interfaces and (if present) a R&S TDU900
display unit must be connected to this R&S TCE900. This
R&S TCE900 can also perform the function of the N+1
automatic system. In addition to functioning as a system
control unit, other functions can also be assigned to the
same R&S TCE900 depending on the modules it con-
tains.
Disabled,
Enabled
Configuration
TX Control Set this check mark if this cassette of the R&S TCE900
cassette is to function as a transmitter control unit. The
transmitter control unit contains, for example, the function
for monitoring the output power and an automatic exciter
switchover function (optional). In addition to functioning
as a transmitter control unit, other functions can also be
assigned to the same R&S TCE900 depending on the
modules it contains. This function must always be activa-
ted together with the "Exciter" function on the same
R&S TCE900.
Disabled,
Enabled
Configuration
Exciter Set this check mark if this R&S TCE900 cassette contains
at least one coder board and one RF board. With a
R&S TCE900 which is configured as an exciter, the "TX
Control" function must be activated at the same time,
unless the R&S TCE900 exciter is to be operated as a
standalone instrument. In addition to functioning as an
exciter, other functions can also be assigned to the same
R&S TCE900 depending on the modules it contains.
Disabled,
Enabled
Configuration
Cooling Con-
trol
Set this check mark if this R&S TCE900 cassette contains
at least one cooling interface or one air cooling interface.
In addition to functioning as a cooling control unit, other
functions can also be assigned to the same R&S TCE900
depending on the modules it contains. The "Cooling Con-
trol" function must always be activated together with the
"Rack Control" function on the same R&S TCE900.
Disabled,
Enabled
Configuration
Basic Settings