Name Description Value range Access right
IP Address
(Remote IP
Settings)
Used to set the IP address of the R&S TCE900 system
control. The settings depend on the network infrastruc-
ture.
Slot Config Used to determine which module is contained in each
installation slot of the R&S TCE900 unit. Basically, any
module can be inserted into any installation slot. The rack
cabling has, however, been optimized for installation of
the modules in the following slots:
Slot A (bottom left): RF board or TX interface
Slot B (top center): Cooling interface (CIF or ACIF)
or ATV interface
Slot C (bottom center): Reserved for receiver module
Slot CD (top right): Coder board or LAN switch
The setting can be changed here.
Coder Board,
RFBoard,
TXIf, Coolin-
gIf, LAN-
SwitchIf,
ATVIf, CIF,
ACIF
Configuration
5.2 Parameters: Input Configuration
GUI name
(external)
Help text (English) Value range Value access
Input Source Here, you can configure the input interfaces used for two inputs, inde-
pendently of each other. To test the "seamless switching" function, it is
possible to select the same input interface for both inputs. The selec-
tion options of the data sources are determined by the installed Input
Interfaces and option keys.
variable Maintenance
Multiplex Name Here, you can assign any desired name for the multiplex contained in
this transport stream. This name is displayed in the transmitter over-
view and, for n+1 systems, in the automatic transmitter.
Maintenance
Mute (on Input
Fail)
Here, you can configure the operating behavior when the active input
fails. This parameter is available in MFN operating mode only.
No – In the operating mode, the output signal is not suppressed if
the active input fails. Null packets are output instead.
Yes - If the active input fails, the output signal is suppressed.
No, Yes Maintenance
Input Fail Delay Used to set a delay time which must elapse following an input signal
failure before the output signal is suppressed and a sum fault is gener-
ated.
Maintenance
Force Exciter
Changeover
Here it can be determined whether switchover to another redundant
exciter is to take place if the input signal fails. This function is available
for all redundancy systems (dual drive, backup exciter and n+1).
Yes - In the "Yes" position, an exciter fault is signaled to the
higherlevel redundancy control unit which decides whether to
switch over to another exciter or transmitter.
No - In the "No" position, no switchover takes place.
Yes, No Maintenance
Monitor Out Here, for measuring purposes, you can send any input signal to the TS
Monitor-Out jack (X22). The selection options of the data sources are
determined by the installed Input Interfaces and option keys.
Maintenance
IP Stream Indicates whether a valid data stream is fed to the transmitter via the IP
feed. If an error is indicated, check the settings of the IP stream and the
Ethernet interface.
Query
Parameters: Input Configuration