SDS

_____________________________________________________________________________________________
1560754 - LGChem Li-ion Battery - ICR18650HE4 Revision Date 19-Feb-2020
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Take off contaminated clothing and wash before
reuse. Do not breathe dust. Avoid generation of dust. In case of insufficient ventilation, wear
suitable respiratory equipment. Handle product only in closed system or provide appropriate
exhaust ventilation. Do not eat, drink or smoke when using this product.
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep out of the reach
of children. Store locked up. Protect from moisture. Store away from other materials.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Limits
.
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Cobalt lithium manganese
nickel oxide
182442-95-1
TWA: 0.02 mg/m
3
Co inhalable
particulate matter TWA: 0.02
mg/m
3
Mn respirable particulate
matter
TWA: 0.1 mg/m
3
Mn inhalable
particulate matter
(vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
Mn
IDLH: 500 mg/m
3
Mn IDLH: 10
mg/m
3
Ni
TWA: 1 mg/m
3
Mn TWA: 0.015
mg/m
3
except Nickel carbonyl
Ni
STEL: 3 mg/m
3
Mn
Phosphate(1-), hexafluoro-,
lithium
21324-40-3
TWA: 2.5 mg/m
3
F TWA: 2.5 mg/m
3
F
(vacated) TWA: 2.5 mg/m
3
IDLH: 250 mg/m
3
F
Aluminum foil
7429-90-5
TWA: 1 mg/m
3
respirable
particulate matter
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable
fraction
(vacated) TWA: 15 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
Supplier Trade Secret
TWA: 0.2 mg/m
3
fume TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu
dust, fume, mist
IDLH: 100 mg/m
3
dust, fume
and mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume
Chemical name Alberta British Columbia Ontario TWAEV Quebec
Cobalt lithium
manganese nickel oxide
182442-95-1
TWA: 0.02 mg/m
3
TWA:
0.2 mg/m
3
TWA: 0.02 mg/m
3
TWA:
0.2 mg/m
3
TWA: 0.02 mg/m
3
TWA: 0.1 mg/m
3
TWA: 0.2 mg/m
3
TWA:
0.02 mg/m
3
Phosphate(1-),
hexafluoro-, lithium
21324-40-3
TWA: 2.5 mg/m
3
TWA: 2.5 mg/m
3
TWA: 2.5 mg/m
3
TWA: 2.5 mg/m
3
Aluminum foil
7429-90-5
TWA: 10 mg/m
3
TWA: 1.0 mg/m
3
TWA: 1 mg/m
3
TWA: 10 mg/m
3
Supplier Trade Secret
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
TWA: 1 mg/m
3
TWA: 0.2 mg/m
3
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
_____________________________________________________________________________________________
Page 5 / 12