SDS

Product name: ROKREZ METALLIC BASE Issue Date: 08/16/2019
Page 4 of 11
holders or monitor nozzles. Immediately withdraw all personnel from the area in case of rising sound
from venting safety device or discoloration of the container. Do not use direct water stream. May
spread fire. Move container from fire area if this is possible without hazard. Burning liquids may be
moved by flushing with water to protect personnel and minimize property damage. Water fog, applied
gently may be used as a blanket for fire extinguishment. Contain fire water run-off if possible. Fire
water run-off, if not contained, may cause environmental damage. Review the "Accidental Release
Measures" and the "Ecological Information" sections of this (M)SDS.
Special protective equipment for firefighters: Wear positive-pressure self-contained breathing
apparatus (SCBA) and protective fire fighting clothing (includes fire fighting helmet, coat, trousers,
boots, and gloves). Avoid contact with this material during fire fighting operations. If contact is likely,
change to full chemical resistant fire fighting clothing with self-contained breathing apparatus. If this is
not available, wear full chemical resistant clothing with self-contained breathing apparatus and fight
fire from a remote location. For protective equipment in post-fire or non-fire clean-up situations, refer
to the relevant sections.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures:
Environmental precautions: Prevent from entering into soil, ditches, sewers, waterways and/or
groundwater. See Section 12, Ecological Information.
Methods and materials for containment and cleaning up: Contain spilled material if possible.
Absorb with materials such as: Sand. Polypropylene fiber products. Polyethylene fiber products.
Remove residual with soap and hot water. Collect in suitable and properly labeled containers.
Residual can be removed with solvent. Solvents are not recommended for clean-up unless the
recommended exposure guidelines and safe handling practices for the specific solvent are followed.
Consult appropriate solvent Safety Data Sheet for handling information and exposure guidelines. See
Section 13, Disposal Considerations, for additional information.
7. HANDLING AND STORAGE
Precautions for safe handling: Avoid prolonged or repeated contact with skin. Avoid contact with
eyes, skin, and clothing. Wash thoroughly after handling. Spills of these organic materials on hot
fibrous insulations may lead to lowering of the autoignition temperatures possibly resulting in
spontaneous combustion. See Section 8, EXPOSURE CONTROLS AND PERSONAL PROTECTION.
Conditions for safe storage: Recommended storage temperature is 55°F (13°C) - 95°F (35°C).
Additional storage and handling information on this product may be obtained by calling your sales or
customer service contact. Ask for a product brochure.
Storage stability
Storage temperature:
Shelf life: Use within
55 - 95 °F (13 - 35 °C) 18 Month
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure limits are listed below, if they exist.