User Manual
Table Of Contents
- USING THE UNIT SAFELY
- IMPORTANT NOTES
- Contents
- Features
- Panel Descriptions
- Setting Up the Kit
- Choosing a Drum Kit
- Playing the Drum Kit
- Creating Your Own Drum Kit
- Playing with the Metronome (Click)
- Playing with a CD, Tape, or MD (Via MIX IN Jack)
- COACH Mode
- Pad Adjustments
- Hi-Hat Control Pedal Adjustment
- Factory Reset (Restoring the Factory Settings)
- About the Pads
- Pad Configuration Possibilities
- Pad and Trigger Settings
- Selecting the Pad Type (Trigger Type)
- Adjusting Pad Sensitivity
- Setting the Minimum Levels for the Pads (Threshold)
- How Playing Dynamics Changes the Volume (Velocity Curve)
- Adjusting the Trigger Signal Detection Time (Scan Time)
- Detecting Trigger Signal Attenuation and Cancelling Incorrect Triggering (Retrigger Cancel)
- Eliminate Crosstalk Between Pads (Crosstalk Cancel)
- Double Triggering Prevention (Mask Time)
- Rim Shots Response (Rim Sensitivity)
- Rim/Edge Dynamic Response (Rim Gain)
- MIDI Settings
- Troubleshooting / Error Messages
- Drum Kit List
- Drum Instrument List
- MIDI Implementation Chart
- Specifications
- Index
56
Pad and Trigger Settings
Important if you are using acoustic drum triggers. Such triggers can produce altered waveforms, which
may also cause inadvertent sounding at Point A in the following figure.
fig.retrigger.e
This occurs in particular at the decaying edge of the waveform. Retrigger Cancel detects such distortion in
and prevents retriggering from occurring.
Although setting this to a high value prevents retriggering, it then becomes easy for sounds to be omitted
when the drums played fast (roll etc.). Set this to the lowest value possible while still ensuring that there is
no retriggering.
You can also eliminate this problem of retriggering with the Mask Time setting. Mask Time
does not detect trigger signals if they occur within the specified amount of time after the
previous trigger signal was received. Retrigger Cancel detects the attenuation of the trigger
signal level, and triggers the sound after internally determining which trigger signals were
actually generated when the head was struck, while weeding out the other false trigger
signals that need not trigger a sound.
1.
Hold down [LEVEL/PAN] and press [TEMPO].
[EDIT] flashes.
2.
Press [EDIT] a few times until “ ” is displayed.
“ ” appears in the display, then the retrigger cancel value is indicated.
3.
Hit the pad you wish to set.
The trigger indicator for the struck pad lights.
4.
Press [+] or [-] to adjust the value.
Retrigger Cancel:
0–15
Making the settings
While repeatedly striking the pad, raise the “Retrigger Cancel” value until retriggering no longer occurs.
5.
Press [EDIT] to continue editing other settings.
6.
When you’re finished, press [DRUM KIT]; the [EDIT] light goes off.
Do not turn off the power without the [EDIT] light having gone out. Otherwise you will lose
the changes you have just made.
Detecting Trigger Signal Attenuation and Cancelling
Incorrect Triggering (Retrigger Cancel)
Time
A