User`s manual

39
AREA AXIS
REPLOT SUBMENU
UNIT AREAUNIT
TOOL-CHG PREFEED
TOOL-CHG COMMAND
IGNORE <EFFECT>
TOOL-CHG:TOOLNO2
Depending on the setting made for "6. Setting for pen change instructions," operation is paused when
a tool-change instruction is received while plotting is in progress. To change the tool, open the front
cover and exchange the tool. Then press the
ENTER
key to resume cutting.
(1) Press the
MENU
key until the screen shown at right appears, then use the and keys
to select "SUBMENU" and press the
ENTER
key.
(2) Press the
ENTER
key, then press the
MENU
key twice the screen shown at right appears.
Then use the
and keys to select "TOOL-CHG" .
(3) Press the
ENTER
key to display the screen shown at right, then use the and keys to
select "EFFECT" and press the
ENTER
key.
11-1 What to do if...
11 What to do if...
Is the power cord connected correctly? Connect the power cord included with the CM-500/400/300 to the unit, and plug
the other end securely into an electrical outlet (see 3-1 Setting Up and Connec-
tion).
CM-500/400/300 troubleshooting
Is the CM-500/400/300 power on ? Turn on the power.
Is the front cover closed? Close the front cover when performing cutting (see 4-2 Loading the Material ).
Is the CM-500/400/300 in the temporary
halt state ? Is operation paused?
If the screen shown at rights is displayed,
it means that operation is paused.
To resume cutting, press the key again.
To abort cutting, first stop the flow of cutting instructions from the computer. And
use the and keys to select "STOP," then press the
ENTER
key.
Are the computer and the CM-500/400/300
linked with the right cable ?
The type of cable you need is determined by your computer and the software you
are using. Even if the computer is the same, running different software may require
a different cable. Use the cable specified in your software.
Check the following items:
DIP switches Memory switches Interface board Communication
parameters Other settings
Read the computer users manual and set it up correctly.
Is the computer set up correctly ?
At the display menus, make the correct settings for the communication parameters
(see 3-3 Selecting the Interface ).
If connected via the serial port, do the
communication parameters for the CM-500/
400/300 match those of the computer ?
PAUSE ON
CONT. STOP VIEW