User`s manual

Part 1
22
Bottom of the head
If the depth regulator nose does not reach the surface of the workpiece
even when the [-Z] key is held down, rotate the micrometer dial in the
direction shown by the arrow in the figure to extent the tip of the depth
regulator nose to the workpiece surface.
If the tip of the depth regulator nose doesn't reach the surface of the
workpiece because the workpiece is too thin, place a board between the
workpiece and the table.
When Using the Depth regulator nose
Using the depth regulator nose makes it possible to engrave even workpiece of non-uniform thickness at the same depth.
Rotate than depth regulator nose in the direction of the
arrow 2 in the figure to tighten it completely.
1
This determines the engraving depth (cutting-in
amount). The scale on the micrometer dial assembly
has 25 grooves, with one groove corresponding to an
engraving depth of 0.0254 mm (0.001 in.). (One full
turn of the scale corresponds to an engraving depth of
0.635 mm (0.025 in.).) Rotate the scale in the
direction of the arrow shown in the figure by an
amount equal to or greater than the engraving depth.
For example, when engraving to a depth of 0.5 mm
(0.0197 in.), the scale should be rotated by 20 grooves
(approximately one full turn). For engraving at a
depth of 1.5 mm (0.0591 in.), rotate the scale by 59
grooves (approximately three turns).
2
Bottom of the head
2
1
Bottom of the head
Loosen the Z adjust screw.
3
Z adjust
screw
Press the arrow keys and the [-Z] key to move the tip
of the depth regulator nose to the surface of the
workpiece.
4
Bottom of the head
Surface of the
workpiece
Table