User`s manual

3 Replacement of Main Parts
53
3
11
Turn on the Power while pressing the [ ], [ ], [ ]
keys to enter the Service Mode.
Select the [LOAD] menu by pressing the [MENU] key and
press [ENTER] key.
12
Select the [AXIS X] in the [LOAD] menu and press [ENTER]
key. Then, Carriage moves to the Limit Position.
Enter the value 500 and press the [ENTER] key.
13
After setting the value, the load check starts.
The Carriage moves in the X direction to check the load.
If the check is OK, fix the Covers.
If the check is NG, repeat 6 to 11 .
CHECK MODE
LOAD CON. CARD
[ ], [ ], [ ] + POWER ON
[ENTER] key
[MENU] key
AXIS X Y Z S
[ENTER] key
AXIS X Y Z S
VALUE 500
[ENTER] key
AXIS X Y Z S
VALUE 500 OK
<X Axis Load Check>
10
Connect the Z Motor Cable, Z Limit Cable and Spindle
Motor Cable to the XZ Junction Board.
Then, fix the Limit Switch and Junction Board Cover.