User`s manual
81
4 Adjustment
4
5
6
7
< X-axis Calibration>
X 230
0.8333
Measured Length
= Calibrating Amount
POWER ON
Check Mode
Check Mode
XY-COMP. Z-COMP.
X-COMP. Y-COMP.
<8333> <8333>
< Example>
When Measured Length is 229.5mm.
X 230
0.8333
229.5
= 0.83512
Measure the both X-axis and Y-axis Length.
Calculate the calibrating amount by the formula shown at
the right.
< Y-axis Calibration>
X 190
0.8333
Measured Length
= Calibrating Amount
< Example>
When Measured Length is 189.5mm.
X 190
0.8333
189.5
= 0.83550
Enter the SERVICE MODE by turning on the power while
pressing [ ], [ ] and [ ] keys and select [XY-COMP.]
under the [Check Mode XY-COMP. Z-COMP.] and press
[ENTER] key.