Owner`s manual

110
Troubleshooting
Problems when using the PCR-M1
Can’t play back / record MIDI
Did you plug in the USB cable, or unplug it while an application was running?
Exit all applications that are using the PCR-M1, and exit all applications that are using the PCR-M1,
and re-connect the PCR-M1.
Is your computer in Suspend or Sleep mode?
If so, get your computer to resume normal operation, then exit all applications that are using the
PCR-M1. Next, turn the PCR-M1’s power off, then switch it on again.
Have you specified the MIDI data output destination in your playback software?
For some software, you may need to specify the PCR-M1 as the output destination for MIDI data.
For details on making this setting, refer to the owner’s manual of the software you are using.
Was the driver installed correctly?
In order for you to play back audio data via the PCR-M1, the driver must be installed. For
installation and settings, refer to
“Getting Connected and Installing Drivers”
(Windows:p. 18/
Macintosh: p. 31).
Are you running multiple applications?
If multiple applications are running simultaneously, an error message may appear. If this occurs,
click
[OK]
and exit the other applications.
Even if an application window is closed, it is still running if it appears in the taskbar. Be sure to exit
unneeded applications displayed.
Playback or recording halts midway through, and then
becomes impossible
Was a heavy processing load experienced while using the PCR-M1, such as accessing
the CD-ROM drive or a network?
If an operation involving a heavy processing load is performed while the PCR-M1 is in use, it may
not operate correctly. If this occurs, stop playback/recording, and then try resuming playback/
recording. If you are still unable to play back/record, exit all applications that use the PCR-M1,
switch off the PCR-M1, then turn it on again.
Operating system becomes unstable
Operation becomes unstable when the computer is started up with the PCR-M1 already
connected
Please start up your computer with the PCR-M1 disconnected, and then connect the PCR-M1. On
a computer that uses a USB keyboard, starting up the computer with the PCR-M1 already
connected may cause operation to become unstable. In this case, start up the computer with the
PCR-M1 disconnected, and then connect the PCR-M1.
The display indicates “Lo.”
When the batteries run low, the display will indicate “Lo.” If this message appears, replace the
batteries as soon as possible.
Replacing the batteries will not erase the contents of user memory.
PCR-M1_e.book 110 ページ 2007年2月5日 月曜日 午前11時19分