User Manual

SYR-E84 units can be stacked.
* In order to stack units, you’ll rst need to remove the modules (including the Eurorack
power supply cables).
* When stacking units, you must attach the covers to prevent the units from overturning.
1.
Remove the two stacking screws from the top
surface of the SYR-E84 that will be on the bottom.
2.
Align the pins of the cover with the holes on the back
panel of the SYR-E84, and use the left and right latches
to secure it.
In the same way, attach the cover to the SYR-E84 that is
to be stacked.
3.
Using the stacking screws that you removed in
step 1, fasten the two SYR-E84 units together.
Secure with latches
Stacking SYR-E84 Units
Before using this unit, carefully read leaet “USING THE UNIT SAFELY.
The bus board of the SYR-E84 provides the following current capacities: +12 V is 2000 mA,
-12 V is 500 mA, and 5 V is 300 mA. When assembling your modules, check the current
consumption of each module and take care not to exceed the allowable capacity for each
voltage.
* If the allowable capacity is exceeded, a safety feature of the bus board will operate, and
power will no longer be supplied.
About the Current Capacity
Use the included Eurorack installation screws to fasten your modules to the rails of the
SYR-E84.
CAUTION
7
Keep small items out of the reach of children
To prevent accidental ingestion of the parts listed below, always keep them out of
the reach of small children.
5
Included Parts: Eurorack installation screws
5
Removable Parts: Stacking screws
Rails
Installing Modules
Power Supply AC adaptor (DC 12 V)
Current Capacity 2000 mA: +12 V 500 mA: -12 V 300 mA: +5 V
Power Consumption 30 W: +12 V 10 W: -12 V 3 W: +5 V
Dimensions 481 (W) x 135 (D) x 157 (H) mm 18-15/16 (W) x 5-3/8 (D) x 6-3/16 (H) inches
Weight 2.4 kg 5 lbs 5 oz
Accessories
Owners manual, Leaet “USING THE UNIT SAFELY, Eurorack Installation
screw (40 pcs.), 16-pin Eurorack power supply cable (2 pcs.), AC adaptor,
Power cord
* In the interest of product improvement, the specications and/or appearance of this unit
are subject to change without prior notice.
Main Specications
Roland SYR-E84: Eurorack Case
The documentation for this unit consists of the following materials.
5
USING THE UNIT SAFELY (separate leaet)
Read this rst. It contains notes that you must observe in order to use the unit correctly.
5
Owners Manual (this document)
This explains how to make connections, and describes the specications of the unit.
About the Manuals
When connected to the bus board, the power supply cable can supply power to up to ten
modules. To connect the power supply cable, grasp the black connector and insert it, making
sure that the wire marked in red is aligned with the white line of the bus board connector.
* When circuit board installation is complete, double-check your work.
WARNING
7
Electrocution hazard
* Before you attach the power supply cable, turn o the power of the
SYR-E84 and disconnect the power plug from the AC outlet.
* Do not touch the electrical terminals when attaching the power supply cable.
Red
White
Connecting the Power Supply Cable
Front side
1
Rails: Use the included screws to fasten your modules to these rails.
2
Bus board area: This is the power supply unit. It provides 12 V, 5 V, and -12 V voltages.
* Do not touch any of the printed circuit pathways or connection terminals.
Rear side
3
AC adaptor connection port: Connect the included AC adaptor here.
* Place the AC adaptor so the side with the indicator faces upwards and the side with
textual information faces downwards. The indicator will light when you plug the AC
adaptor into an AC outlet.
4
Power switch: Turns the power of the bus board on/o.
* This unit is equipped with a protection circuit. A brief interval (a few seconds) after
turning the unit on is required before it will operate normally.
21
Part Names and Descriptions
3 4
Owner’s manual English Copyright © 2015 ROLAND CORPORATION
* 5 1 0 0 0 4 9 0 7 3 - 0 2 *

Summary of content (1 pages)