Owner`s manual
111
System settings
System settings
1.
In the top panel’s DISPLAY section, press [SETUP].
2.
At the SETUP screen, select “SYSTEM“ and press [ENTER].
The SYSTEM screen is displayed.
At the SYSTEM screen, you can make the following settings:
SAMPLING FREQ
This selects the sampling frequency at which the M-200i
operates. You can select either 48 kHz or 44.1 kHz.
CH-MUTE OPTION
You use this to set how a channel mute button behaves
when pressed.
Items displayed with “ON” are enabled. The selection items
are as follows:
MAIN MUTE
This enable or disable the top panel [MUTE] for MAIN.
AUTO OFF
This button accesses the AUTO OFF screen for setting the
function to turn off the power automatically (p. 111).
DISPLAY/PANEL
This button accesses the DISPLAY/PANEL screen for setting
the brightness and contrast of the panel and display (p. 112).
DATE/TIME
This button accesses the DATE/TIME screen for setting the
date and time (p. 112).
DELAY UNIT
This selects the unit used for delay at the CHANNEL EDIT
screens (AUX, MTX, or MAIN) and the MONITOR screen.
The selection items are as follows:
This sets the function for turning off the power automatically.
1.
Access the SYSTEM screen.
2.
Select “AUTO OFF“ and press [ENTER].
The AUTO OFF screen is displayed.
Select one of the following as the AUTO OFF time:
When the auto-off function has been turned on, a message
informing you that auto-off is on is displayed at startup (p. 15).
Accessing the SYSTEM screen
Mutes AUX/MTX
SENDS
Turning this on makes the input-channel muting
also mute out sends to AUX and MTX.
Mutes DIRECT
OUTS
Turning this on makes the input-channel muting
also mute out DIRECT OUTs.
1
2
3
4
5
6
ms
Milliseconds
Feet Feet
Meter Meters
Frame Frames (24, 25, 29.97, or 30 fps)
Sample Sample
Setting the auto-off function
OFF
The auto-off function is disabled.
8HOURS The power is turned off automatically if 8 hours pass
without any controller being operated.
7