An Error Message Appears
6
FAQ
158
[TEMPERATURE IS TOO HIGH **°C]
The temperature of the location where the machine is installed has risen above the ambient
temperature at which the machine can operate.
Operation cannot be continued. Switch o the sub power. The displayed temperature is the current ambient
temperature of the installation location. Bring the installed location to a temperature at which operation is
possible (15 to 32°C) and allow the machine to come to room temperature, then turn on the power.
[SERVICE CALL xxxx]
An unrecoverable error occurred, or part replacement that must be performed by a service
technician is required.
Note the number displayed, then switch o the sub power. After you switch o the power, inform your autho-
rized Roland DG Corp. dealer of the number that appeared on the display.
[SHEET TOO SMALL CONTINUE?]
The size of the data is larger than the printing or cutting area of the loaded media.
To continue performing output without correcting this, press . At this time, the portion extending
beyond the printing or cutting area is not output. To stop output, stop sending data from the computer, then
raise the loading lever. Make the printing or cutting area wider, such as by replacing the media with a larger
piece of media or by changing the positions of the pinch rollers, then send the data again.
[SHEET SET ERROR SET AGAIN]
The loading lever was lowered while no media was loaded.
Raise the loading lever, place media at the correct location, then lower the lever again.
P. 35, “Loading Media”
[EDGE DETECTION] is set to "ENABLE," but transparent media was loaded.
Raise the loading lever, set the [EDGE DETECTION] menu item to "DISABLE," then reload the media.
P. 110, "Speeding Up Output for Narrow Media"
The loaded media is too small.
Press any key to clear the error. Replace with media of usable size.
[TEMPERATURE IS TOO LOW **°C]
The temperature of the location where the machine is installed has fallen below the ambient
temperature at which the machine can operate.
Operation cannot be continued. Switch o the sub power. The displayed temperature is the current ambient
temperature of the installation location. Bring the installed location to a temperature at which operation is
possible (15 to 32°C) and allow the machine to come to room temperature, then turn on the power.
[DATA ERROR CANCELING...]
Output was stopped because a problem was found in the data received.
Operation cannot be continued. Check for a problem with the connector cable or the computer, and redo the
operation from the step of loading the media.