User`s manual

Specications
7
Main
Specications
167
*1
Note: The media holder of this machine is exclusive use for the media of paper tube (core) inner diameter 3 inches. To use 2 inches media, the optional
media anges are required.
*2
The length of printing or cutting is subject to the limitations of the program.
*3
Media type: Media specied by Roland DG Corp. (Cutting only)
Temperature: 25°C (77°F), humidity: 50%
Roll media must be loaded correctly.
Applicable when all pinch rollers available to the media width are used.
Side margins: 25 mm or more for both the left and right margins
Front margin: 35 mm or more
Excluding expansion/contraction of the media
Not assured when the print heater or dryer is used.
All correction or adjustment function of this machine has been made properly.
*4
With Roland PET lm, print travel: 1 m
*5
[PREFEED] menu item must be set to "ENABLE."
Range for assured repetition accuracy
64-inch model
For media with a width exceeding 610 mm: Length 4,000 mm
For media with a width of 610 mm or less: Length 8,000 mm
54-inch model
For media with a width exceeding 610 mm: Length 4,000 mm
For media with a width of 610 mm or less: Length 8,000 mm
42-inch model
Length 3,000 mm
30-inch model
Length 3,000 mm
*6
Provided that media length is under 3,000 mm
Excludes the eects of slanted movement and of expansion and contraction of the media.
*7
Data size:
64-inch model:1,000 mm in the media-feed direction, 1,600 mm in the carriage-movement direction
54-inch model:1,000 mm in the media-feed direction, 1,346 mm in the carriage-movement direction
42-inch model:1,000 mm in the media-feed direction, 1,046 mm in the carriage-movement direction
30-inch model:1,000 mm in the media-feed direction, 736 mm in the carriage-movement direction
No lamination
Automatic detection of crop marks at 4 points when media is reloaded.
During cutting, [PREFEED] menu item must be set to "ENABLE."
Excluding possible shift caused by expansion/contraction of the media and/or by reloading the media.
*8
Warm-up is required after power up. This may require 5 to 20 minutes, depending on the operating environment.
Depending on the ambient temperature and media width, the preset temperature may fail to be reached.
*9
Operating environment
Use in an operating envi-
ronment with this range.