Programming Instructions

Table Of Contents
15 | Automate™ Programming Instructions | Cord Lift Motor with Extended P1 Button Cable
Problem Cause Remedy
Motor is not responding
A / C Adapter not plugged in.
Check motor to power cable
connection and AC plug.
Battery in battery pack is depleted Replace 8xAA alkaline batteries.
Power failure.
Check power supply to motor is
connected and active
Transmitter battery is discharged Replace battery
Battery is inserted incorrectly into
transmitter.
Check battery polarity
Radio interference/shielding.
Ensure transmitter is positioned
away from metal objects and the
aerial on motor or receiver is kept
straight and away from metal
Receiver distance is too far from
transmitter.
Move transmitter to a closer
position
Incorrect wiring.
Check that wiring is connected
correctly (refer to motor
installation instructions)
Unable to adjust or set limits. Remote is in a locked state.
Change remote status to an
unlocked state
Cannot program a single Motor
(multiple motors respond)
Multiple motors are paired to the
same channel.
Always reserve an individual
channel for programming
functions
SYSTEM BEST PRACTICE - Provide
an extra 15 channel remote in your
multi motor projects, that provides
individual control for each motor
for programming purposes
Place all other motors into sleep
mode (ref to P1 function overview
- section 3.2 and 10.1)
11 TROUBLESHOOTING
ROLLEASE ACMEDA
AUSTRALIA
110 Northcorp Boulevard,
Broadmeadows VIC 3047
T +61 3 9355 0100 | F +61 3 9355 0110
ROLLEASE ACMEDA
USA
200 Harvard Avenue
Stamford, CT 06902 6320
T +1 203 964 1573 | F +1 203 964 0513
ROLLEASE ACMEDA
EUROPE
Via Conca Del Naviglio 18, Milan
(Lombardia) Italy
T +39 02 8982 7317 | F +39 02 8982 7317
Queensland Branch
Unit 2/62 Borthwick Avenue,
Murarrie QLD 4172
info@rolleaseacmeda.com
rolleaseacmeda.com