User's Manual

RONDISH STRIP DOOR MONITOR DMS-02
DRAWING No.
001/3V2
TITLE
MODEL No.
Wiring for door monitor strips
DMS-02
12Vdc 500mA regulated
power input
12Vdc (1 amp max) alarm contact output for flash
light, or other indicating device (optional)
12Vdc (1amp max) output to energise door lock (optional)
Please refer to User Instruction manual
Electric door lock
Magnetic door contacts(optional)
Refer to J15
0V 12VContact
Refer to J11
Alarm
(Com)
Lock +12V
0V N/C TX Reset
Reset
(Contact, keypad, card reader etc)
Please refer to drawing 001V2
for alternative Reset connection
Wired data Tx
Typically 4 core telephone type cable
to CMU-02
via
CMJ-01 junction box
NOTE: Power, Lock and Magnertc Door Contact connections are duplicated at both ends of
strip sensor units unit for convenience of connection.
Connect magnetic contacts in series
(for two door strips and/ordouble doors)
Connect in parallel
(for two door strips and/or
two door locks)
Connect 12V power supply
in parallel (for two door strips)