6.3 QUICK PROGRAMMING GUIDE (001/5 – 001/6)
DOOR MONITOR QUICK PROGRAMMING PROCEDURE
Step 3:
(i) Press and hold programme mode button until you hear three(3) fast beeps.
Set door number on rotary programming switch.(1-F)
(ii) Press mode button until you hear one (1) "beep".
Set area code number e.g. "0" will be received by any Central Monitor.
(iii) Press and hold programme mode button until you hear two (2) beeps..
Set door "extension" code (required when two, or more monitor strips are used for one
door). This code is set e.g. on the first strip monitor as 1 and a second strip on the same door as 2.
note. Set to zero if one unit or used with older versions of door monitors.
(iv) Press and hold programme mode button until you hear three (3) beeps.
Set door lock time number. These are set at 5 second intervals - example 3=15 seconds
5 = 25 seconds, F(15) = 75 secs. Note. 0 = always on in alarm.
(v) Press program button until hear 2 beeps and after a few seconds unit will
beep 4 times and exit program mode.
Testing after programming a door monitor
You now need to test into a central monitor by setting off an alarm with a
wristband and checking door number dsiplayed. If central monitor does not receive the alarm you may
need to check the area code is set correctly. (set central monitor to zero area code and try again
to test if this is the problem).
NOTE:
If the area code on the central monitor is set differently to
the door monitor (unless one is zero) it will not receive the signal.
If two door monitors are programmed to the same door number i.e. on the same door and
you find the signal is not reliable to the central monitor especially when a door contact is used and during a
alarm reset this probbaly means the door extension number has not been set correctly. Try reprogramming
the units ensuring these are set to different numbers. (eg 1, 3, etc)
Check the door lock time (buzzer steady on ) is correct (usually set to 15 secs) with a watch etc.