User's Manual Part 2


Notes:
1. The Call Point Zone Address code can be chosen and set for 00-63 within the
operating area of an individual Zone Protektor. This address tells the Care
Station how to contact the Call Point, and must not be repeated for each ZP.
2. The Site/Area code allows a Slave Monitor to display alarms from only its
area. The Slave Station, Zone Protektor and Call Point areas must match.
40(- "1+! "
With the programmer still powered up, you may then continue by keying # again and
inputting the string. This string will not always need to be entered.
The program string is #010 P LL G. Where:
# = “Ready to Program”
010 = Device Configuration Program Code
P = Product Type (3 = “Bath Alarm Button” or 8 = “Call Point”)
LL = Presence Area (0-31)
G = Group Reset Facility (0 = Turn Off, 1 = Turn On).
Presence Area (LL)
Caregiver may press the “Presence button to light the green colour at the indication
Call Light and notify the Master Caregiver Station of location, ID and ”Presence 1.
While this Call Point is in “Presence” mode, if another Call within the zone with the
same “Presence” code (Presence Area) is activated, the Call Point will alert the
caregiver another call has been activated from within it’s “Presence Area” with a
flashing LED and beeping at intervals of 15s.
Group Reset (G)
Within a particular Zone Protektor “Zone”, if “G is turned on (i.e. set to “1”), operating
any single Call Point “Reset” button with this Protektor zone location will reset any, or
all activated Call Point/s that have been programmed for “Group Reset On” in that
Protektor zone.