258 Section 8 Troubleshooting
8.5 Event Notification Response
When you select Event Notification, the Galaxy Array Manager sends popup and/or email messages
regarding its status. The messages you see depend on your notification selection and what is currently
happening in the Galaxy3G. See “Setting-up User Event Subscriptions”.
The table below cites:
• Reported Events – Events that require you to take action
• Corrective Actions – The action you should take in response to the event
A list of event categories is shown below.
•
Battery
•
Blowers
•
Cache
•
Controller
•
Disk Array
•
Drive Interface
Controller
•
Enclosure
•
Event Log
•
Fibre Channel
•
Host Interface
Controller
•
Logical Drive
•
Media Patrol
•
Online Capacity
Expansion
•
PDM
•
Physical Disk
•
PSU (Power Supply Units)
•
PSU Fans
•
RAID Level Migration
•
Rebuild
•
Redundancy Check
•
Resource
•
Spare Check
•
Spare Drives
•
SMART
•
Stripe Level Migration
•
Synchronization
•
System (Galaxy3G)
•
Transition
•
Watermark
Reported Event Corrective Action
Battery
Battery temperature is
above the threshold
The battery is too hot. Verify proper airflow around
the through the Galaxy3G. If airflow is OK, replace
the battery.
Battery temperature is
normal
Normal.
Battery capacity is below
the threshold
Battery is drained. Run battery reconditioning.
Battery capacity is normal Normal.
Battery is discharging Battery is undergoing reconditioning.
Battery is charging Battery is being recharged.