Product manual

Galaxy G3G12 / G3G16 - Installation and Hardware Reference Manual
261 Section 8 Troubleshooting
Drive-interface
diagnostics has passed
Normal.
Drive-interface
diagnostics has failed
Restart the Galaxy3G. If this message appears
repeatedly, contact Technical Support.
Drive-interface controller
has generated a
general/data parity error.
Drive-to-controller parity error. If this message
appears repeatedly, contact Technical Support.
Enclosure
Enclosure temperature is
above the
threshold/warning
threshold
The Galaxy3G is overheating. Check for airflow
around and through the Galaxy3G, and verify that all
fans are working. Replace fans as needed.
Enclosure temperature is
above the critical
threshold
The Galaxy3G is seriously overheating. Check for
airflow around and through the Galaxy3G, and verify
that all fans are working. Replace fans as needed.
Enclosure temperature is
within the normal range
Normal.
Event Log
Event logging is enabled Event logging has been successfully enabled.
Event logging is disabled Event logging has been disabled.
Event log buffer is
cleared in RAM
The event log was cleared.
Event log buffer is
cleared in NVRAM
The non-volatile RAM event log was cleared.
Event log buffer is
cleared in MDD
The MDD (disk drive) event log was cleared.
Fibre Channel
Fibre Channel controller
has detected bus reset
The initiator sent a reset command. If this message
appears repeatedly, contact Technical Support.
Fibre Channel controller
has received a LUN reset
command.
Result of user action. Normal.
Fibre Channel controller
has encountered a fatal
error
Restart the Galaxy3G. If this message appears
repeatedly, contact Technical Support.
Fibre Channel link is up FC link connected and ready. Normal.
Fibre Channel link is
down
FC link disconnected or otherwise not working.