Operating instructions
PAGE 6  www.rosco.com  GENERAL INSTRUCTIONS 
simply an indication to the operator that the fluid level should be checked and will not affect 
the performance. Because the bottles will “self-level” a Low Fluid Sensor is only required in 
one bottle. 
Pump Cut Off: The Delta 6000 is also equipped with a thermal cut-off that is attached to the 
pump. If the machine is running when the fluid bottle is empty, the pump could start to 
overheat at which time the thermal sensor will cut off power to the pump. Avoid running the 
machine without fog fluid to prevent damage to the pump. 
CAUTION: The machine only works with uncontaminated Rosco fog fluids. Other 
manufacturers’ fluids may cause spitting and serious clogging problems and could result 
in the production of an unhealthful aerosol. The use of other fluids voids the warranty of 
the Rosco Delta 6000 fog machine. 
5.  0-10 VOLT INPUT 
In addition to operating directly from the remote controls and a DMX console, the Rosco 
Delta 6000 is also equipped to operate from a 0-10 volt input. The input is located on the rear 
of the machine near the DMX connectors. The 0-10 volt input is wired through an RJ-11 
connector. Pin 1 is positive and pin 4 is negative. The 0-10 volt input will ONLY operate the 
Delta with a remote attached and power turned on at the remote. 
6.  AIR INPUT 
The Delta 6000 is equipped with Air Input located at the rear of the machine. This is to allow 
the use of compressed air to clean the heat exchanger. In addition, compressed air can be used 
for effects. 