Instruction manual

Orion Installation and Operations Manual
47
Telegrams, Switching functions Switch Matrix
No
Function
Telegram
Reply
11
Set Switch Matrix (Complete Setup):
• requires 48 values (first 16 CPU’s,
then 32 CON Ports)
• 0x80 for “No Output“
• CON01…CON16
Output Signal from
CPU#1…CPU#16
(cf. Telegram 3)
• CPU01…CPU32
Output Signal from
CON#1…CON#32
(cf. Telegram 7)
Attention: Correct
assignment to be
ensured by user!
Attention: only 16
CON Ports available,
requires 16x 0x80!
STX, 0x51,
<CPU#1>,
<CPU#2>,
…,
<CPU#16>,
<CON#1>,
<CON#2>,
…,
<CON#32>,
ETX
ACK, ECHO
12
Reset Switch Matrix
STX, 0X52, ETX
ACK
13
Report Switch Matrix
(Complete Setup)
• Output of 48 values
• 0x80 for
„No Output“
• The first 16 values
describe CON Port
Output
(cf. Telegram 3)
• The next 32 values
describe the CPUOutput
(cf. Telegram 7)
STX, 0x53, ETX
STX, 0x53,
<CPU#1>,
<CPU#2>,
…,
<CPU#16>,
<CON#1>,
<CON#2>,
…,
<CON#32>,
ETX
Save / Load Switch
Matrix
14
Save Matrix
Configuration to Flash
STX, 0x66, 0x8C,
<Config File No >,
ETX
ACK
15
Load Matrix
Configuration from
Flash
STX, 0x67, 0x8C,
<Config File No >,
ETX
ACK, ECHO
(contains
Complete Setup)
Assignment of Configuration Files to Telegram
Configuration Files
Config File No
Configuration Files
Config File No
Default.sys
0x80
Config05.sys
0x85
Config01.sys
0x81
Config06.sys
0x86
Config02.sys
0x82
Config07.sys
0x87
Config03.sys
0x83
Config08.sys
0x88
Config04.sys
0x84