5.3.2 Connect the FG3 to a 3 pin J1939 Connector (Heavy Duty Vehicle)
If the vehicle has a 3 pin Deutsch connector for electronic instrumentation, perform the
following:
Run a twin wire cable from the vehicle connector to the FG3 as follows:
1. Connect the CAN_H from pin B of the Deutsch connector to the FG3 point CAN_H.
2. Connect the CAN_L pin A of the Deutsch connector to the FG3 point CAN_L.
3. Connect pin C ground of the Deutsch connector to the FG3 point BATT (-).
DT06-3S-E008 Connector
3 PIN Deutsch DT06-3S-E008 Connector- Pin Out
Pin
Function
Description
CAN-L
CAN-H
CAN-GND
CAN ground
CAN bus dominant low
CAN bus dominant high
A
B
C
A B
C
1
.
5
M
e
t
e
r
Slim RF Antenna with
Adhesive
-
Black
BATTERY
12VDC
+
Fuse 3A
IN PUT 2
IN PUT 1
DALLAS LED
IMMOBILIZER
DALLAS IN
(-) BAT OUT
(-) BAT IN
(+) BAT OUT
(+) BAT IN
CAN L (-)
ACC CANBUS
POWER/RF
GPS/GPRS
PROG
GPS
CAN H(+)
DC-EO
VSS
12V / 24V
RID-FG3-03
Ignition switch
Pin C - J1939
Pin B - J1939
Pin A - J1939
GPRS
ROSEMAN
FLEET GATE
Figure 7: Wiring Diagram for FG3 with CAN Bus Interface (3-pin connector) for Heavy Duty Vehicles