Reference Manual
Table Of Contents
- Rosemount 1408A Level and Flow Transmitter
- Contents
- 1 Introduction
- 2 Transmitter overview
- 3 Mechanical installation
- 4 Electrical installation
- 5 Configuration
- 6 Operation and maintenance
- 7 Service and troubleshooting
- 7.1 Safety messages
- 7.2 Diagnostic messages
- 7.2.1 Device hardware fault – Device exchange
- 7.2.2 Device software fault – Check firmware revision
- 7.2.3 General power supply fault – Check availability
- 7.2.4 Parameter error – Check data sheet and values
- 7.2.5 Device memory failure – Restore default settings
- 7.2.6 Simulation active – Check operational mode
- 7.2.7 Level measurement lost – Check application
- 7.2.8 Device temperature over-run – Clear source of heat
- 7.2.9 Device temperature under-run – Insulate device
- 7.2.10 Short circuit – Check installation
- 7.2.11 Primary supply voltage over-run – Check tolerance
- 7.2.12 Primary supply voltage under-run – Check tolerance
- 7.2.13 Maintenance required - Cleaning
- 7.2.14 Max EEPROM write cycles expired – Check master and restart the device
- 7.2.15 Measurement range over-run – Check application
- 7.3 Troubleshooting incorrect level readings
- 7.3.1 Reported level is too high or low
- 7.3.2 Level is stuck in measuring range
- 7.3.3 Level is stuck in full tank
- 7.3.4 Level value drops when close to antenna
- 7.3.5 Measured level fluctuates
- 7.3.6 Measured level is occasionally unstable
- 7.3.7 Lagging of measured level
- 7.3.8 Incorrect level at 100% (20 mA)
- 7.3.9 Incorrect level when product surface is above 50%
- 7.3.10 Dropping of level close to tank bottom
- 7.3.11 Level measurement is lost in an empty tank
- 7.3.12 Alarm mode close to tank bottom
- 7.4 Managing disturbance echoes
- 7.5 Service and troubleshooting tools
- 7.6 Service support
- A Specifications and reference data
- A.1 Performance specifications
- A.2 Functional specifications
- A.3 Physical specifications
- A.4 Dimensional drawings
- B Product certifications
- C Configuration parameters
Figure 6-1: Dashboard
Need help?
Select the Help button for more information on the features and capabilities.
6.2.1 Measurement variables
Variable Description
Level The current level measurement value (from the zero level to the product
surface).
Distance The distance from the transmitter reference point to the surface.
Signal strength The reflected signal strength from the surface.
Electronics
temperature
The current temperature at the electronics.
Min electronics
temperature
The measured minimum electronics temperature.
Max electronics
temperature
The measured maximum electronics temperature.
Volume Flow The calculated volume flow value.
6.2.2 Interpret measurement status
A “Good” or “Bad” status next to a value is an indication of the reliability or integrity of the
data being received, not an indication of whether or not the value is within the configured
upper or lower ranges. A value that triggers an alert, such as a high or low temperature
indication, will change the overall status of the device, but the measurement might still be
indicated as “Good” if the reliability of the data is good.