Declaration of Conformity

1 Product certifications
Rev 0.20
1.1 European directive and UKCA regulations information
A copy of the EU/UKCA Declaration of Conformity can be found at the end of
this document. The most recent revision of the EU/UKCA Declaration of
Conformity can be found at Emerson.com/Rosemount.
1.2 Safety Instrumented Systems (SIS)
SIL 3 Capable: IEC 61508 certified for use in safety instrumented systems up
to SIL 3 (Minimum requirement of single use (1oo1) for SIL 2 and redundant
use (1oo2) for SIL 3).
1.3 Ordinary location certification
As standard, the transmitter has been examined and tested to determine
that the design meets the basic electrical, mechanical, and fire protection
requirements by a nationally recognized test laboratory (NRTL) as accredited
by the Federal Occupational Safety and Health Administration (OSHA).
1.4 Environmental conditions
Table 1-1: Environmental Conditions (Ordinary Location and Low
Voltage Directive (LVD))
Type Description
Location Indoor or outdoor use
Maximum altitude 6562 ft. (2000 m)
Ambient temperature -67 to +185 °F (-55 to +85 °C)
Installation category DC supplied
Electrical supply 12-35 Vdc, 1 W
Mains supply voltage fluctuations Safe at 12-35 Vdc ±10%
Pollution degree 2
1.5 Telecommunication compliance
Measurement principle
Frequency Modulated Continuous Wave (FMCW), 80 GHz
Maximum output power
+5 dBm (3.2 mW)
Product Certifications September 2022
2 Rosemount 3408 Level Transmitter