Users Manual Part 1

6.4 Check device status
The device reports diagnostic alerts when there is a device malfunction.
Procedure
1.
Go to the Overview screen to view the overall device status.
2. If status is anything other than Good, select the button in the device status image to
open a window with Active Alerts.
Active Alerts can also be obtained via Service Tools Alerts.
Related information
Diagnostic messages per NAMUR NE 107
6.4.1 Device status images
Table 6-2: Device Status Images in DD
Device status image Category Description Action
Good No active alert. N/A
Failure At least one Failure alert is
active.
Click the Troubleshoot button
to open a window with active
alerts together with
recommended actions.
Function Check At least one Function Check alert
is active (and no Failure alerts).
Click the Investigate button to
open a window with active alerts
together with recommended
actions.
Out of
Specification
At least one Out of Specification
alert is active (and no Failure or
Function Check alerts).
Maintenance
Required
At least one Maintenance
Required alert is active (and no
Failure, Function Check, or Out
of Specification alerts).
Operation and maintenance Reference Manual
September 2022
00809-0100-4418
50 Emerson.com/Rosemount