Users Manual Part 1

Related information
Use the simulation mode
Restart the device
7.2.11 Electronics temperature out of limits
Category
Out of Specification
Cause
The temperature of the electronics board has exceeded the transmitter’s operating range.
Recommended actions
1.
Verify ambient temperature is within the operating range.
2. Remote mount the transmitter away from the process and environmental
conditions.
Related information
Ambient temperature
7.2.12 Low signal quality
Category
Maintenance Required
Cause
The Signal Quality is below the defined alert limit.
Recommended actions
1. Take action based on your intended use of this alert.
2. Clean the antenna.
3. If no actions were necessary, consider to change the limit.
Related information
Signal quality alert
7.2.13 High user defined alert
Category
Maintenance Required
Cause
The user defined variable is above the defined limit.
Recommended actions
1.
Bring the system to a safe state.
2. Verify that the process variable is within specified limits.
3. Reconfirm the user defined alarm limit.
Service and troubleshooting Reference Manual
September 2022 00809-0100-4418