Users Manual Part 1

Table 7-1: Echo Peak Types
Type Description
Surface Echo tracked as the current surface echo
Unknown Echo not recognized by the device, which might
interfere with measurement
Suppressed Echoes that are identified but suppressed by the
device
Suppressed (double bounce) Echo managed as a double bounce echo by the
Double Bounce function
Secondary surface Echo tracked as the current secondary surface (if
Double Surface Handling function is enabled)
Tank bottom echo Echo considered as an echo from the tank
bottom
Figure 7-16: Echo Curve with Typical Echo Peaks
C
meter
0
0 1 000 2 000 3 000 4 000 5 000 6 000 7 000 mV
0.5
1.0
1.5
2.0
2.5
3.0
3.5
D
A
E
AB
A. Suppressed (dashed line indicates use of false echo suppression)
B.
False echo suppression
C. Unknown
D. Amplitude threshold
E. Surface
Reference Manual Service and troubleshooting
00809-0100-4418
September 2022
Rosemount 3408 Level Transmitter 87