Users Manual Part 1

2. Type the desired register number to start reading from.
In Rosemount Radar Master Plus, registers can also be viewed by selecting a group
from the Block list.
3.
Select Read Input Registers (Refresh in Rosemount Radar Master Plus).
4. (Handheld communicator) Select Input Registers.
7.4.11 View holding registers
The holding registers store various transmitter parameters, such as configuration data,
used to control the measurement performance.
Procedure
1.
Select Configure (Manual Setup) Level Setup Advanced Expert Options
Holding Registers.
2. Type the desired register number to start reading from.
In Rosemount Radar Master Plus, registers can also be viewed by selecting a group
from the Block list.
3. Select Read Holding Registers (Refresh in Rosemount Radar Master Plus).
4. (Handheld communicator) Select Holding Registers.
7.4.12 Edit holding registers
Edit holding registers using Rosemount Radar Master Plus
Prerequisites
Note
Do not use holding registers to configure the transmitter unless you are qualified. This
dialog is mainly used for service purposes and for advanced configuration.
Procedure
1.
To change a holding register value, type a new value in the corresponding value
field, or select a new value from the corresponding list.
2. Select Save to store the new value.
Edit holding registers in DD compliant host
Prerequisites
Note
Do not use holding registers to configure the transmitter unless you are qualified. This
dialog is mainly used for service purposes and for advanced configuration.
Procedure
In the Holding Registers tab, select Write Holding Register and follow the on-screen
instructions.
Reference Manual Service and troubleshooting
00809-0100-4418
September 2022
Rosemount 3408 Level Transmitter 93