Users Manual Part 1

Related information
Restore to default settings
Configure transmitter using guided setup
Threshold configuration error
Cause
The surface threshold configuration is incorrect.
Recommended actions in UIP
1.
Adjust the threshold as necessary.
2. If condition persists, restore default settings and reconfigure device.
Recommended actions in DD
1. In the threshold table, check that distance-threshold values are entered in
increasing order.
2. Check that the number of threshold points to use is correct.
3. If condition persists, restore default settings and reconfigure the device.
Related information
Amplitude threshold
Restore to default settings
Configure transmitter using guided setup
Factory approval error
Cause
The Sensor Module factory approval is missing.
The Transmitter factory approval is missing.
Note
This error may also be set as a result of the startup failure. If both errors are present, then
see the startup failure message.
Recommended actions
1.
Restart the device.
2. Restore default settings and reconfigure device.
3. If the condition persists, replace the device.
Related information
Restart the device
Restore to default settings
Configure transmitter using guided setup
Reference Manual Service and troubleshooting
00809-0100-4418
September 2022
Rosemount 3408 Level Transmitter 61