User's Guide
Table Of Contents
- Contents
- About this manual
- 1 Introduction
- The TankRadar Pro System
- Measurement Principle
- 2 Mechanical Installation
- Socket Requirements
- Free Space Requirements
- Dimensions
- Tools
- Mounting the Rod Antenna
- Mounting the Cone Antenna - PTFE sealing
- Mounting the Cone Antenna - Quartz Sealing
- Mounting the Cone Antenna - Process Seal
- Mounting the Parabolic Antenna
- 3 Electrical Installation
- Identication of Installed Options
- Junction Box
- External Connections
- Connecting to a TRL2 Bus Interface
- Connecting HART devices
- Connecting the Display Panel
- Cables
- Safety
- Power Supply
- Grounding
- System Overview
- Internal Connections
- 4 Pro Setup Software
- System Requirements
- Installing the Pro setup software
- Starting the Pro Setup Program
- Setting a Password
- Logging on to a password protected system.
- Setting measurement units
- Installing a Pro Transmitter
- Viewing Level Data
- Service
- 5 Using the Pro Display Panel
- Operation
- Viewing Level Data
- Installing a Pro Transmitter
- Service
- 6 Tank Distances
- Definitions
- Examples
- 7 Technical Information
- Technical Data
- Display Panel
- Analog Outputs
- 8 Troubleshooting
- Display Panel Error Messages
Saab TankRadar
®
Pro Mechanical Installation
2-5
Edition 2. Ref. No: 306010E
Flange adapter
Flange
Nut
Wave guide
tube
Tank flange diameter = 65 mm (3)
1. Carefully center the flange adap-
ter on top of the tank flange.
Use gaskets under and above the
flange adapter.
2. Insert the antenna into the socket.
Mount the loose flange and
tighten the screws.
3. Insert the wave
guide tube into
the upper wave
guide.
Make sure that
all parts are
clean and dry.
4. Place the transmitter on top of the
antenna and tighten the nut.
5. Make sure that all nuts and bolts are
tightened.
Proceed with the electrical installation