User's Guide
Table Of Contents
- Contents
- About this manual
- 1 Introduction
- The TankRadar Pro System
- Measurement Principle
- 2 Mechanical Installation
- Socket Requirements
- Free Space Requirements
- Dimensions
- Tools
- Mounting the Rod Antenna
- Mounting the Cone Antenna - PTFE sealing
- Mounting the Cone Antenna - Quartz Sealing
- Mounting the Cone Antenna - Process Seal
- Mounting the Parabolic Antenna
- 3 Electrical Installation
- Identication of Installed Options
- Junction Box
- External Connections
- Connecting to a TRL2 Bus Interface
- Connecting HART devices
- Connecting the Display Panel
- Cables
- Safety
- Power Supply
- Grounding
- System Overview
- Internal Connections
- 4 Pro Setup Software
- System Requirements
- Installing the Pro setup software
- Starting the Pro Setup Program
- Setting a Password
- Logging on to a password protected system.
- Setting measurement units
- Installing a Pro Transmitter
- Viewing Level Data
- Service
- 5 Using the Pro Display Panel
- Operation
- Viewing Level Data
- Installing a Pro Transmitter
- Service
- 6 Tank Distances
- Definitions
- Examples
- 7 Technical Information
- Technical Data
- Display Panel
- Analog Outputs
- 8 Troubleshooting
- Display Panel Error Messages
Saab TankRadar
®
ProPro Setup
4-16
Edition 2. Ref. No: 306010E
solved by changing the mechanical instal-
lation. Related database register:
DoubleBounceOffset
(1522).
Slow search
See description of the Standard tab pa-
rameters. Related database register:
SearchSpeed
(1524).
Double surface
Indicates that there are two liquids in the
tank resulting in two reflecting surfaces.
The upper liquid is must to be partly trans-
parent to the radar signal. If this function is
activated, you can specify which surface to
ignore by setting the
Ignore top surface
parameter.
Ignore top surface
This function should only be used if
DoubleSurface
is set. See description of
Double surface
. If
IgnoreTopSurface
is set
the lower surface will be presented as the
product surface.
Show negative values
See description of the Standard tab
as zero
parameters.
Monotone ullage/level
When a tank is filled the level value may
presentation
fluctuate up and down due to a turbulent
surface. By setting this parameter the
transmitter will not present decreasing
level values for a tank that is being filled
unless the level decreases more than an
amount given by the
MonFilt Hysteresis
parameter (holding register 1058).
For a tank that is being emptied only
decreasing values are presented, unless
the level rises more than an amount given
by the
MonFilt Hysteresis
parameter.