User's Guide
Table Of Contents
- Contents
- About this manual
- 1 Introduction
- The TankRadar Pro System
- Measurement Principle
- 2 Mechanical Installation
- Socket Requirements
- Free Space Requirements
- Dimensions
- Tools
- Mounting the Rod Antenna
- Mounting the Cone Antenna - PTFE sealing
- Mounting the Cone Antenna - Quartz Sealing
- Mounting the Cone Antenna - Process Seal
- Mounting the Parabolic Antenna
- 3 Electrical Installation
- Identication of Installed Options
- Junction Box
- External Connections
- Connecting to a TRL2 Bus Interface
- Connecting HART devices
- Connecting the Display Panel
- Cables
- Safety
- Power Supply
- Grounding
- System Overview
- Internal Connections
- 4 Pro Setup Software
- System Requirements
- Installing the Pro setup software
- Starting the Pro Setup Program
- Setting a Password
- Logging on to a password protected system.
- Setting measurement units
- Installing a Pro Transmitter
- Viewing Level Data
- Service
- 5 Using the Pro Display Panel
- Operation
- Viewing Level Data
- Installing a Pro Transmitter
- Service
- 6 Tank Distances
- Definitions
- Examples
- 7 Technical Information
- Technical Data
- Display Panel
- Analog Outputs
- 8 Troubleshooting
- Display Panel Error Messages
Saab TankRadar
®
Pro Pro Setup
4-27
Edition 2. Ref. No: 306010E
To add points to the diagram:
1 Place the mouse pointer in the diagram
at the position where you want to add a
point to the Amplitude Threshold curve.
2 Click the right-hand mouse button and
select Add point,
- or-
click the Add button in the Spectra-
Threshold window.
Note! The Amplitude Threshold Table
displays the position of the currently
selected point, not the position of the added point.
To move points:
Select the point to be moved and
drag to desired position,
- or -
select the point and specify new
position and amplitude in the Ampli-
tude threshold table.
To remove points:
1 Select the point to be removed.
2 Click the Delete button in the Spectra-
Threshold window.
Do not create noise thresholds around echoes which are already
registered as interfering echoes. The general amplitude threshold
is the lower limit of the noise threshold table:
Selected Point
Position
and
amplitude
Delete button
Add button