User's Guide
Table Of Contents
- Contents
- About this manual
- 1 Introduction
- The TankRadar Pro System
- Measurement Principle
- 2 Mechanical Installation
- Socket Requirements
- Free Space Requirements
- Dimensions
- Tools
- Mounting the Rod Antenna
- Mounting the Cone Antenna - PTFE sealing
- Mounting the Cone Antenna - Quartz Sealing
- Mounting the Cone Antenna - Process Seal
- Mounting the Parabolic Antenna
- 3 Electrical Installation
- Identication of Installed Options
- Junction Box
- External Connections
- Connecting to a TRL2 Bus Interface
- Connecting HART devices
- Connecting the Display Panel
- Cables
- Safety
- Power Supply
- Grounding
- System Overview
- Internal Connections
- 4 Pro Setup Software
- System Requirements
- Installing the Pro setup software
- Starting the Pro Setup Program
- Setting a Password
- Logging on to a password protected system.
- Setting measurement units
- Installing a Pro Transmitter
- Viewing Level Data
- Service
- 5 Using the Pro Display Panel
- Operation
- Viewing Level Data
- Installing a Pro Transmitter
- Service
- 6 Tank Distances
- Definitions
- Examples
- 7 Technical Information
- Technical Data
- Display Panel
- Analog Outputs
- 8 Troubleshooting
- Display Panel Error Messages
Saab TankRadar
®
ProPro Display Panel
5-12
Edition 2. Ref. No: 306010E
NEXTBACK
SETUP MENU
Display Panel
Guided...
Advanced...
SAVEMARKCNCL
SET ANTENNA TYPE
User defined
Std Cone 4" P
Std Cone 4" Q
HP Cone 4" P
HP Cone 4" Q
Std Cone 6" P
481A70E9705159F2
3. Select “Guided...” from the Setup Menu and
press the
NEXT
button.
4. Confirm your Start Code by selecting the
SAVE
button.
The transmitter is delivered with a start
code that enables the ordered software
options. If you wish to change the set of
available options, (Saab´s echofixer, Mul-
tiple Echo Tracking™ (MET), Fast High
Accuracy Signal Technique™ (FHAST) and
strapping table volume calculation), contact your local representative for
a new start code.
6. Set the Antenna Type.
Press the button to move the cursor to
the desired antenna, and click the
MARK
button to select it.
HP=high performance (Hastelloy, Tanta-
lum, Titanium, Monel),
Std=standard,
P=PTFE tank sealing,
Q=quartz sealing,
C=Ceramic.
Finish by pressing the
SAVE
button.
5. Note the available software options. (To
see all options use the arrow button to
scroll down the list. Strap table is the last
one).
Go to the next menu by selecting the
OK
button.