User's Guide

Saab TankRadar
®
ProPro Display Panel
5-22
Edition 2. Ref. No: 306010E
EDITCNCL
TANK ECHOES
Surface 10.543 m
Echo 1 -0.213 m
Echo 2 1.629 m
Echo 3 7.867 m
Echo 4 20.620 m
Echo 5 21.001 m
Tank Echoes
Reg. False Echoes
FALSE ECHO
BACK
NEXT
8. Select the False Echo option from the Advanced Setup menu (optional).
In normal operation the gauge compares
detected echoes with a list of registered
disturbance echoes, in order to decide wich
one is the actual product surface.
To view a list of echoes that the gauge has
detected select the Tank Echoes option.
5 Repeat steps 1 to 4 if you wish to register more disturbing echoes.
The Set as surface option allows you to define an echo as the
product surface.
Mark the Add new false option if you want to manually add echoes.
This may be a useful option if, for example, there are known distur-
bances below the product surface which can not be detected by the
gauge at the time of installation.
6 Click the
CNCL
button to return to the False Echo menu.
To view the current list of registered disturbing echoes select the Reg. False
Echoes option:
You can select echoes from this list and
add to the list of registered echoes. You
should only register disturbing echoes
which can be identified as caused by an
object in the tank. See chapter 5
Pro Setup
Software
for further information on when to
register disturbance echoes.
To register a disturbing echo, do the
following:
1 Move the cursor to the echo you want
to add to the list.
2 Click the
EDIT
button.
3 Move the cursor to Add to list, and
click the
MARK
button.
4 Click the
SAVE
button to register the
marked echo.