4-2
VERIFY OPERATION Operation can be verified in three locations: at the device, by using the 475
Field Communicator, at the Smart Wireless Gateway’s integrated web
interface or via AMS Wireless Configurator.
Troubleshooting
If the device is not joined to the network after power up, verify the correct
configuration of the Network ID and Join Key, and verify that Active
Advertising has been enabled on the Gateway. The Network ID and Join Key
in the device must match the Network ID and Join Key of the Gateway.
Field Communicator
A 708 DD is required for HART communication. For connecting with a Field
Communicator, refer to Figure 2-2 on page 2-3.
Smart Wireless Gateway
In the integrated web interface from the Gateway, navigate to the
Explorer>Status page. This page shows whether the device has joined the
network and if it is communicating properly.
NOTE:
The time to join the new device(s) to the network is dependent upon the
number of devices being joined and the number of devices in the current
network. For one device joining an existing network with multiple devices, it
may take up to five minutes. While it may take up to 60 minutes for multiple
new devices to join the existing network.
NOTE:
If the device joins the network and immediately has an alarm present, it is
likely due to sensor configuration. Check the sensor configuration (see Fast
Key Sequence on page 2-5).
Function Key Sequence Menu Items
Communications 3,3 Join Status, Wireless Mode, Join
Mode, Number of Available
Neighbors, Number of
Advertisements Heard, Number of
Join Attempts