User's Manual

Table Of Contents
108
Reference Manual
00809-0100-4100, Rev AA
Appendix A: Specifications and Reference Data
June 2012
Specifications and Reference Data
Standard Standard
0 Not Applicable or Customer Supplied
Expanded
1 Gate Valve, Carbon Steel
2 Gate Valve, Stainless Steel
5 Ball Valve, Carbon Steel
6 Ball Valve, Stainless Steel
Temperature Measurement
Standard Standard
T Integral RTD – not available with Flanged model greater than class 600#
0 No Temperature Sensor
Expanded
R Remote Thermowell and RTD
Transmitter Connection Platform
Standard Standard
3 Direct-mount, Integral 3-valve Manifold– not available with Flanged model greater than class 600
5 Direct -mount, 5-valve Manifold – not available with Flanged model greater than class 600
7 Remote-mount NPT Connections (
1
/2-in. NPT)
Expanded
6 Direct-mount, high temperature 5-valve Manifold – not available with Flanged model greater than
class 600
8 Remote-mount SW Connections (
1
/2-in.)
Differential Pressure Range
Standard Standard
1 0 to 25 in H
2
O (0 to 62,3 mbar)
2 0 to 250 in H
2
O (0 to 623 mbar)
3 0 to 1000 in H
2
O (0 to 2,5 bar)
Transmitter Output
Standard Standard
X Wireless
Transmitter Housing Material Conduit Entry Size
Standard Standard
P Engineered polymer No conduit entries
Transmitter Performance Class
Standard Standard
1 1.6% flow rate accuracy, 8:1 flow turndown, 5-yr. stability
Wireless options (Requires option code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART
PlantWeb Diagnostic Functionality
Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information