User's Manual

Table Of Contents
123
Reference Manual
00809-0100-4100, Rev AA
Appendix A: Specifications and Reference Data
June 2012
Specifications and Reference Data
4
(1)
10K per JIS B2238 316 SST
5
(1)
20K per JIS B2238 316 SST
6
(1)
40K per JIS B2238 316 SST
Seal Fill Fluid (High Side) Specific Gravity
Temperature Limits (Ambient Temperature of
70° F (21° C))
Standard
Standard
A Syltherm XLT 0.85 -102 to 293 °F (-75 to 145 °C)
C Silicone 704 1.07 32 to 401 °F (0 to 205 °C)
D Silicone 200 0.93 -49 to 401 °F (-45 to 205 °C)
H Inert (Halocarbon) 1.85 -49 to 320 °F (-45 to 160 °C)
G Glycerine and
Water
1.13 5 to 203 °F (-15 to 95 °C)
N Neobee M-20 0.92 5 to 401 °F (-15 to 205 °C)
P Propylene Glycol
and Water
1.02 5 to 203 F (-15 to 95 °C)
Low Pressure Side
Configuration
Flange
Adapter
Diaphragm Material Sensor Fill Fluid
Standard
Standard
11
(1)
Gage SST 316L SST Silicone
21
(1)
Differential SST 316L SST Silicone
22
(1)
Differential SST Alloy C-276 Silicone
2A
(1)
Differential SST 316L SST Inert (Halocarbon)
2B
(1)
Differential SST Alloy C-276 Inert (Halocarbon)
31
(1)
Tuned-System
Assembly with
Remote Seal
None 316L SST Silicone
(Requires Option Code S1)
O-ring
Standard
Standard
A Glass-filled PTFE
Housing Material Conduit Entry Size
Standard
Standard
P Engineered polymer No conduit entries
Wireless options (Requires option code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART
Antenna and SmartPower
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
Options (Include with selected model number)
Seal Assemblies
Table 6. Rosemount 3051L Level Transmitter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.