User's Manual
Table Of Contents
- 2051_Wireless_revAA_6-7
- Rosemount 2051 Wireless Series
- Contents
- Section 1: Introduction
- Section 2: Configuration
- 2.2.1 Warnings () 6
- 2.3.1 Connection Diagrams 6
- 2.4.1 Join Device to Network 7
- 2.4.2 Configure Update Rate 8
- 2.4.3 Remove Power Module 8
- 2.5.1 Review Pressure Information 9
- 2.5.2 Review Device Information 9
- 2.5.3 Review Sensor Information 11
- 2.5.4 Review Radio Information 11
- 2.7.1 Operating Parameters 14
- 2.8.1 Set Process Variable Unit 14
- 2.8.2 Set Transfer Function 16
- 2.8.3 Damping 17
- 2.8.4 Write Protect 17
- 2.9.1 LCD Display Configuration 18
- 2.10.1 Configure Process Alarms 19
- 2.10.2 Sensor Temperature Unit 20
- 2.11.1 Master Reset 20
- 2.11.2 Join Status 20
- 2.11.3 Number of Available Neighbors 21
- 2.12.1 Saving, Recalling, and Cloning Configuration Data 22
- Section 3: Installation
- 3.2.1 Warnings () 26
- 3.3.1 General 27
- 3.3.2 Wireless 27
- 3.3.3 Mechanical 27
- 3.3.4 Environmental 28
- 3.4.1 Mount the Transmitter 29
- 3.4.2 Process Connections 32
- 3.4.3 Consider Housing Rotation 34
- 3.4.4 Grounding 34
- 3.4.5 Power Module Installation 35
- 3.4.6 Installing the LCD Display 35
- 3.5.1 Rosemount 305 Integral Manifold Installation Procedure 37
- 3.5.2 Rosemount 306 Integral Manifold Installation Procedure 37
- 3.5.3 Rosemount 304 Conventional Manifold Installation Procedure 38
- 3.5.4 Manifold Operation 38
- Section 4: Commissioning
- Section 5: Operation and Maintenance
- 5.2.1 Sensor Trim overview 48
- 5.2.2 Zero Trim 49
- 5.2.3 Sensor Trim 49
- 5.2.4 Recall Factory Trim—Sensor Trim 50
- 5.2.5 Line Pressure Effect (Range 2 and Range 3) 50
- 5.2.6 Compensating for Line Pressure (Range 4 and Range 5) 50
- 5.3.1 Startup Screen Sequence 53
- 5.3.2 Diagnostic button screen sequence 55
- 5.3.3 Network diagnostic status screens 56
- 5.3.4 Device Diagnostic Screens 59
- Section 6: Troubleshooting
- 6.2.1 Warnings () 63
- 6.3.1 Remove from Service 67
- 6.3.2 Remove Feature Assembly 68
- 6.4.1 Reassemble the Process Flange 69
- A.3.1 Range and Sensor Limits 75
- A.6.1 Options (Include with selected model number) 86
- A.6.2 Options (Include with selected model number) 93
- A.6.3 Options (Include with selected model number) 98
- A.6.4 Options (Include with selected model number) 105
- A.6.5 Options (Include with selected model number) 110
- A.6.6 Options (Include with selected model number) 115
- B.1.1 Approved manufacturing locations 119
- B.1.2 European directive information 119
- B.1.3 Telecommunication compliance 119
- B.1.4 FCC and IC 119
- B.1.5 Ordinary location certification for FM 119
- B.1.6 North American certifications 120
- B.1.7 CSA - Canadian Standards Association 120
- B.1.8 European certifications 120
- B.1.9 Japanese Certifications 121
- B.1.10 China (NEPSI) Certifications 121
- Section 1 Introduction
- Section 2 Configuration
- Section 3 Installation
- Section 6 Troubleshooting
- Appendix A Specifications and Reference Data
- Appendix B Product Certifications
- 3051_Wireless_revAA_6-7
- Rosemount 3051 Wireless Series
- Contents
- Section 1: Introduction
- 1.2.1 Rosemount 3051CD Differential Pressure Transmitter 1
- 1.2.2 Rosemount 3051CG Gage Pressure Transmitter 1
- 1.2.3 Rosemount 3051CA Absolute Pressure Transmitter 1
- 1.2.4 Rosemount 3051T Gage and Absolute Pressure Transmitter 2
- 1.2.5 Rosemount 3051L Liquid Level Transmitter 2
- 1.5.1 Wireless considerations 5
- 1.5.2 Mechanical 6
- 1.5.3 Electrical 6
- 1.5.4 Environmental 6
- Section 2: Configuration
- 2.2.1 Warnings () 10
- 2.3.1 Connection Diagrams 10
- 2.4.1 Join Device to Network 11
- 2.4.2 Configure Update Rate 12
- 2.4.3 Remove Power Module 12
- 2.5.1 Review Pressure Information 13
- 2.5.2 Review Device Information 13
- 2.5.3 Review Sensor Information 15
- 2.5.4 Review Radio Information 15
- 2.7.1 Operating Parameters 17
- 2.8.1 Set Process Variable Unit 17
- 2.8.2 Set Transfer Function 19
- 2.8.3 Damping 20
- 2.8.4 Write Protect 20
- 2.9.1 LCD Display Configuration 21
- 2.10.1 Configure Process Alarms 22
- 2.10.2 Sensor Temperature Unit 23
- 2.11.1 Master Reset 23
- 2.11.2 Join Status 23
- 2.11.3 Number of Available Neighbors 24
- 2.12.1 Saving, Recalling, and Cloning Configuration Data 25
- Section 3: Installation
- 3.2.1 Warnings () 28
- 3.3.1 General 29
- 3.3.2 Wireless 29
- 3.3.3 Mechanical 29
- 3.3.4 Environmental 30
- 3.4.1 Mount the Transmitter 31
- 3.4.2 Process Connections 34
- 3.4.3 Consider Housing Rotation 36
- 3.4.4 Grounding 36
- 3.4.5 Power Module Installation 37
- 3.4.6 Installing the LCD Display 37
- 3.5.1 Rosemount 305 Integral Manifold Installation Procedure 39
- 3.5.2 Rosemount 306 Integral Manifold Installation Procedure 39
- 3.5.3 Rosemount 304 Conventional Manifold Installation Procedure 40
- 3.5.4 Manifold Operation 40
- Section 4: Commissioning
- Section 5: Operation and Maintenance
- 5.2.1 Sensor Trim Overview 52
- 5.2.2 Zero Trim 53
- 5.2.3 Sensor Trim 53
- 5.2.4 Recall Factory Trim—Sensor Trim 54
- 5.2.5 Line Pressure Effect (Range 2 and Range 3) 54
- 5.2.6 Compensating for Line Pressure (Range 4 and Range 5) 54
- 5.3.1 Startup Screen Sequence 57
- 5.3.2 Diagnostic Button Screen Sequence 59
- 5.3.3 Network Diagnostic Status Screens 60
- 5.3.4 Device Diagnostic Screens 63
- Section 6: Troubleshooting
- 6.2.1 Warnings () 68
- 6.3.1 Removing from Service 72
- 6.3.2 Removing the electronics board 73
- 6.3.3 Removing the sensor from the housing 74
- 6.5.1 Attaching electronics board 75
- 6.5.2 Reassembling the 3051C process flange 75
- 6.5.3 Installing drain/vent valve 77
- A.1.1 Conformance to specification (±3s (Sigma)) 79
- A.1.2 Digital Output 79
- A.1.3 Reference Accuracy 80
- A.1.4 Flow performance - flow reference accuracy 80
- A.1.5 Total Performance 81
- A.1.6 Long Term Stability 82
- A.1.7 Dynamic Performance 82
- A.1.8 Line Pressure Effect per 1000 psi (6,9 MPa) 82
- A.1.9 Ambient Temperature Effect per 50°F (28°C) 83
- A.1.10 Mounting Position Effects 83
- A.1.11 Vibration Effect 83
- A.1.12 Power Supply Effect 83
- A.1.13 Electromagnetic Compatibility (EMC) 83
- A.2.1 Service 84
- A.2.2 Range and Sensor Limits 85
- A.2.3 Zero and Span Adjustment Requirements 85
- A.3.1 Overpressure Limits 86
- A.3.2 Static Pressure Limit 87
- A.3.3 Burst Pressure Limits 87
- A.3.4 Temperature limits 87
- A.3.5 Humidity Limits 88
- A.3.6 Volumetric Displacement 88
- A.3.7 Damping 88
- A.4.1 Process Connections 89
- A.4.2 Process-Wetted Parts 89
- A.4.3 Rosemount 3051L process wetted parts 90
- A.4.4 Non-Wetted Parts 90
- A.4.5 Shipping Weights for 3051 Wireless Pressure Transmitter 91
- A.5.1 Ordering Information 95
- A.5.2 Rosemount 3051C Coplanar Pressure Transmitter 95
- A.5.3 Rosemount 3051T In-Line Pressure Transmitter 101
- A.5.4 Rosemount 3051CF Flowmeter Series 105
- A.5.5 Rosemount 3051L Level Transmitter 121
- B.1.1 Approved manufacturing locations 143
- B.1.2 European directive information 143
- B.1.3 Telecommunication compliance 143
- B.1.4 FCC and IC 143
- B.1.5 Ordinary location certification for FM 143
- B.1.6 North American certifications 144
- B.1.7 CSA - Canadian Standards Association 144
- B.1.8 European certifications 144
- B.1.9 Japanese Certifications 145
- B.1.10 China (NEPSI) Certifications 145
- Section 1 Introduction
- Section 2 Configuration
- Section 3 Installation
- Section 4 Commissioning
- Section 5 Operation and Maintenance
- Section 6 Troubleshooting
- Appendix B Product Certifications
- Section 1: Introduction
87
Reference Manual
00809-0100-4102, Rev AA
Appendix A: Reference Data
June 2012
Specifications and Reference Data
Alternate Flange
(4)
Standard Standard
H2 Traditional Flange, 316 SST, SST Drain/Vent ★
H3
(3)
Traditional Flange, Alloy C, Alloy C-276 Drain/Vent ★
H4 Traditional Flange, Cast Alloy 400, Alloy 400/K-500 Drain/Vent ★
H7
(3)
Traditional Flange, 316 SST, Alloy C-276 Drain/Vent ★
HJ DIN Compliant Traditional Flange, SST,
1
/16 in. Adapter/Manifold Bolting ★
FA Level Flange, SST, 2 in., ANSI Class 150, Vertical Mount ★
FB Level Flange, SST, 2 in., ANSI Class 300, Vertical Mount ★
FC Level Flange, SST, 3 in., ANSI Class 150, Vertical Mount ★
FD Level Flange, SST, 3 in., ANSI Class 300, Vertical Mount ★
FP DIN Level Flange, SST, DN 50, PN 40, Vertical Mount ★
FQ DIN Level Flange, SST, DN 80, PN 40, Vertical Mount ★
Expanded
HK
(5)
DIN Compliant Traditional Flange, SST, 10 mm Adapter/Manifold Bolting
HL DIN Compliant Traditional Flange, SST, 12mm Adapter/Manifold Bolting (Not available on 2051CD0)
Manifold Assembly
(5)(9)
Standard Standard
S5 Assemble to Rosemount 305 Integral Manifold ★
S6 Assemble to Rosemount 304 Manifold or Connection System ★
Integral Mount Primary Element
(5)(9)
Standard Standard
S4
(6)
Assemble to Rosemount Annubar or Rosemount 1195 Integral Orifice ★
S3 Assemble to Rosemount 405 Compact Orifice Plate ★
Seal Assemblies
(9)
Standard Standard
S1
(7)
Assemble to one Rosemount 1199 seal ★
S2
(8)
Assemble to two Rosemount 1199 seals ★
All-Welded Seal Assemblies (for high vacuum applications)
(9)
Standard Standard
S0 One Seal, All-Welded System (Direct Mount Connection Type) ★
S7 One Seal, All-Welded System (Capillary Connection Type) ★
S8 Two Seals, All-Welded System (Capillary Connection Type) ★
S9 Two Seals, All-Welded System (One Direct Mount and One Capillary Connection Type) ★
Table A-5. 2051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.