Reference Manual
00809-0100-4102, Rev AA
Appendix A: Reference Data
June 2012
Specifications and Reference Data
Shipboard Approvals
Standard Standard
SBS American Bureau of Shipping
Display and Interface Options
Standard Standard
M4
(8)
LCD Display with Local Operator Interface
M5 LCD Display
Transient Protection
Standard Standard
T1
(9)
Transient terminal block
Manifold for Remote Mount Option
Standard Standard
F2 3-Valve Manifold, Stainless Steel
F6 5-Valve Manifold, Stainless Steel
PlantWeb Control Functionality
Standard Standard
A01
(10)
FOUNDATION fieldbus Advanced Control Function Block Suite
PlantWeb Diagnostic Functionality
Standard Standard
D01
(10)
FOUNDATION fieldbus Diagnostic Suite
Wireless Transmit Rate, Operating Frequency and Protocol
Standard Standard
WA3 User Configurable Transmit Rate, 2.4 GHz WirelessHART
Antenna and SmartPower
Standard Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
Low Power Output
Standard Standard
C2
(11)
0.8-3.2 V dc Output with Digital Signal Based on Hart Protocol
Alarm Limit
Standard Standard
C4
(11)
(12)
NAMUR Alarm and Saturation Levels, High Alarm
CN
(11)(12)
NAMUR Alarm and Saturation Levels, Low Alarm
Hardware Adjustments
Standard Standard
DZ Digital Zero Sensor Trim Configuration Button
Ground Screw
Standard Standard
V5
(13)
External Ground Screw Assembly
Typical Model Number: 2051CFC D C S 060 N 065 0 3 2 A A 1 WC E5 M5
(1) Not available for Primary Element Technology C.
(2) For 2-in. (50 mm) line sizes the Primary Element Type is 0.6 for Primary Element Technology Code C.
(3) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(4) Not available with Primary Element Technology P.
(5) Not available with F
OUNDATION fieldbus (Output Code F) or Profibus (Output Code W).
(6) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(7) Not available with Low Power code M.
(8) Available only with output code W - Profibus PA.
(9) The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product Certification code IA.
(10) Only valid with F
OUNDATION fieldbus Output Code F.
(11) Not available with F
OUNDATION fieldbus (Output Code F) or Profibus (Output Code W).
(12) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(13) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
Table A-9. Rosemount 2051CFC Compact Flowmeter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.