User manual
Technical data
Dimension
Height 1850 mm
Width 595 mm
Depth 623 mm
Voltage 230 V
Frequency 50 Hz
The technical information are situated in the rating plate
on the internal left side of the appliance and in the ener-
gy label.
Installation
Caution! Read the "Safety Information" carefully
for your safety and correct operation of the
appliance before installing the appliance.
Positioning
Install this appliance at a location where the ambient
temperature corresponds to the climate class indicated
on the rating plate of the appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
Location
To ensure best performance, if the appliance is posi-
tioned below an overhanging wall unit, the minimum
distance between the top of the cabinet and the wall
unit must be at least 40 mm . Ideally, however, the ap-
pliance should not be positioned below overhanging
wall units.
The ventilation space can
be:
• directly above the ap-
pliance
• behind and above the
top cupboard.
In this case, the space
behind the top cup-
board must be at least
50 mm deep.
50mm
Electrical connection
Before plugging in, ensure that the voltage and fre-
quency shown on the rating plate correspond to your
domestic power supply.
The appliance must be earthed. The power supply ca-
ble plug is provided with a contact for this purpose. If
the domestic power supply socket is not earthed, con-
nect the appliance to a separate earth in compliance
with current regulations, consulting a qualified electri-
cian.
The manufacturer declines all responsibility if the above
safety precautions are not observed.
This appliance complies with the E.E.C. Directives.
Removing the transport support
Your appliance is equipped with transport support to
secure the door during transportation.
To remove them do these steps:
11