User Manual
Table Of Contents
- Candy UM_mixed_EL.pdf
- Σημαντικές προειδοποιήσεις
- Ηλεκτρική σύνδεση
- Σύνδεση αερίου
- Εισαγωγή της συσκευής
- Τεχνικά χαρακτηριστικά
- Εγκατάσταση της επιφάνειας εστιών
- Διαστάσεις αποκοπής πάγκου
- Πίνακας ελέγχου
- Χρήση της επιφάνειας εστιών
- Συντήρηση και καθαρισμός
- Αντιμετώπιση προβλημάτων
- Κανόνες χειρισμού
- Διάθεση φιλική προς το περιβάλλον
- Πληροφορίες για τη συσκευασία
- Candy UM_mixed_it.pdf
- Avvertenze importanti
- Collegamento elettrico
- Collegamento gas
- Introduzione dell'elettrodomestico
- Caratteristiche tecniche
- Installazione del piano di cottura
- Dimensioni di taglio del ripiano della cucina
- Pannello comandi
- Uso del piano di cottura
- Manutenzione e pulizia
- Risoluzione degli inconvenienti
- Regole di gestione
- Smaltimento rispettoso dell'ambiente
- Informazioni sull'imballaggio
- Candy UM_mixed.doc_en-GB_pt-PT.pdf
- Caro utilizador,
- “Em conformidade com os regulamentos REEE.”
- AVISOS IMPORTANTES
- Ligação elétrica
- Esquema da ligação elétrica
- Ligação à rede de gás
- Para a ligação de LPG;
- Quanto à ligação de gás natural;
- Transformação de gás natural para LPG e de LPG para gás natural
- Ventilação da divisão
- APRESENTAÇÃO DO ELETRODOMÉSTICO
- Características técnicas
- Injetor, circulação de gás e tabela de potência
- INSTALAÇÃO DA PLACA
- Local correto para a instalação
- Instalação
- Diagrama da instalação
- Se o forno de encastrar for montado por baixo da placa;
- Medidas do corte da bancada
- PAINEL DE CONTROLO
- Painel de visualização da placa de 60 cm
- Painel de visualização da placa de 45 cm
- Painel de visualização da placa de 30 cm
- UTILIZAÇÃO DA PLACA DE COZEDURA
- Queimador do wok *
- MANUTENÇÃO E LIMPEZA
- DETEÇÃO E RESOLUÇÃO DE PROBLEMAS
- Pontos de verificação
- REGRAS DE MANUSEAMENTO
- ELIMINAÇÃO AMIGA DO AMBIENTE
- INFORMAÇÕES CONTIDAS NA EMBALAGEM
16
5. After that, detach control switches of the cooktop. Make setting by
turning the screw in the middle of gas cocks with a small screwdriver in
the manner shown in the following picture. To adjust ow rate screw, use
a screwdriver having suitable dimension. For LPG, turn the screw clockwise.
For natural gas, turn the screw one time counter clockwise. At low
position, length of normal ame should be 6-7 mm. For the last control,
check out whether ame is open or closed.
Setting of your appliance may differ according to the type of gas cock used.
Ventilation Of Room
The air needed for burning is received from room air and the gases emitted
are given directly in room. For safe operation of your product, good room
ventilation is a precondition. If no window or room to be utilized for room
ventilation is available, additional ventilation should be installed. However,
room has a door opening outside, it is no needed to vent holes.
Room size Ventilating opening
Smaller than 5 m³ min. 100 cm²
Between 5 m³ - 10 m³ min. 50 cm²
Bigger than 10 m³ no need
In basement or cellar min. 65 cm²
Figure 4 Figure 5