user manual

it is possible to set a maximum power absorption level for the induction hob, choosing up to different
power ranges.
induction hobs are able to limit themselves automatically in order to work at lower power level, to
avoid the risk of overloading.
Power Management Function
To lock the controls
Touch and hold the Timer “ ” and Timer ”
at the same time for a while.
The timer indicator will show “ Lo ”
To unlock the controls
Touch and hold the Timer “ ” and Timer ”
at the same time for a while.
When the hob is in the lock mode, all the controls are disable except the ON/OFF , you can always turn the induction hob
off with the ON/OFF control in an emergency, but you shall unlock the hob first in the next operation.
To enter Power Management Function
Turn on the hob, then Press at the same time
the Pause key and Timer ”
”.
The timer indicator will show “ P5“ which
means power level 5The default mode is on
To switch to another level
press +/- of the timer
or
There are 5 power levels, from P1to p5”.
The timer indicator will show one of them.
P1” : the maximum power is 2.5 .
P2” : the maximum power is 3.5 .
P3” : the maximum power is 4.5 .
P4” : the maximum power is 5.5 .
P5” : the maximum power is 7.0 .
EN-10
ENGLISH
7.0
k
W
k
W
k
W
k
W
k
W
k
W
.