User Manual

Table Of Contents
sources from the video server are taken on-air. This
trigger can be set up to occur automatically any time the
video source is transitioned on-air, or it can be triggered
manually.
An automatic GPI output trigger can be overridden if
required.
Note: The Next Button Secondary Function must be set to GPO
to be able to trigger a GPI output manually using the NEXT
button.
Keep the following in mind when working with GPI
output triggers:
The RlClip knob must be set to On to trigger a GPI
output with a transition.
Edge triggered GPI outputs remain triggered for the
congured duration.
Level triggered GPI outputs toggle between high and
low each time they are triggered.
To Manually Trigger a GPI Output
The GPI must already be set up as a output and the Next
button functionality must be set to GPO before you can
manually trigger it.
1.
Press and hold the NEXT button.
While holding the Next button, the pattern buttons
light for each GPI output that is currently triggered.
2.
Press the pattern button for the GPI output you want
to trigger. The numbers on the pattern buttons
correspond to the GPI.
To Override a GPI Output
The RlClip personality option must be set to User for
you to override GPI output triggering.
1.
Prepare the transition as required, but do not perform
the transition.
2.
Press the transition type button again to bring up the
transition menus.
3.
Use the RlClip knob to select whether the GPI
output is triggered (On), or is not triggered (Off).
26 Transitions Carbonite Black Solo Operation Manual (v1.2)