User Manual
Table Of Contents
- United States of America — FCC Part 15
- Canada
- Europe
- International
- Contents
- Features
- Clean Feed Output
- Custom Controls
- Device Control
- DVE (Fly Key)
- Effects Dissolve
- General Purpose Interface (GPI)
- LiveEDL
- Matte/Wash Generator
- ME Effect System
- Media-Store
- MediaManager
- MediaWipe
- MemoryAI Recall Mode
- Memory System
- MiniME™
- MultiScreen
- MultiViewer
- Pattern and Matte/Wash Generators
- Tally Outputs
- UltraChrome
- Control Panel Overview
- Menu System
- Switcher Basics
- DashBoard
- ViewControl
- Transitions
- Patterns, Washes, and Mattes
- Keying
- Memory Functions
- Memory Access Mode
- Storing Memories
- Recalling Memories
- Memory Recall Mode
- Memory Attributes
- To Set the Program Bus Source Attribute
- To Set the Preset Bus Source Attribute
- To Set the Transition Type Attribute
- To Set the Next Transition Attribute
- To Set the Run Auto Trans Attribute
- To Set the Shared Pattern Generator Attribute
- To Set the Key Bus Sources Attribute
- To Set the Key On-Air Attribute
- To Set the Key Type Attribute
- To Set the Key Mask Attribute
- To Set the Media-Store Attribute
- To Set the Aux Bus Attribute
- To Set the Camera Shot Attribute
- To Set the Roll GPO Attribute
- To Set the Roll VTR Attribute
- Clear Memories
- Switcher Sets
- Media-Store
- Custom Controls
- Switcher Soft Reset
- Glossary
- Index

DescriptionLocationEvent
Select the line in the VANC that the
EmbeddedTriggers message will be
inserted on.
Switcher
Installation >
Embedded
Trigger >
Settings
EmbeddedTriggers
— Set Line
1. Click Line
2. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
3. Enter the line value you want to
use in the Value field.
Select the remote ID you want to use
to identify the switcher that the
Switcher
Installation >
EmbeddedTriggers
— Set Remote ID
EmbeddedTriggers message is coming
from.
Embedded
Trigger >
Settings
1. Click Remote ID
2. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
3. Enter the remote ID value you
want to use in the Value field.
Select the secondary data identifier
word (SDID) you want to use for the
EmbeddedTriggers message.
Switcher
Installation >
Embedded
Trigger >
Settings
EmbeddedTriggers
— Set SDID
1. Click SDID
2. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
3. Enter the SDID value you want
to use in the Value field.
Assign DVE resources (Fly) to the
selected key for the selected ME,
MiniME
™
, or MultiScreen.
Switcher >
Keyer > Keyer
Fly
Fly Key (DVE)
1. Click the ME button and select
the ME, MiniME
™
, or
MultiScreen that you want to
perform the event on.
2. Click the Keyer button for the
key you want to perform the
event on.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
4. Click the Value button and select
whether DVE resources are
assigned to the key (On) or not
(Off).
Set up the type of edge trigger for the
GPI output.
Devices > GPOGPI Output — Edge
Trigger Setup
1. Click GPO Edge Duration
2. Click the GPO button and select
the GPI output that you want to
configure.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
DescriptionLocationEvent
the parameter. Some selections
will not be available when you
reset the parameter.
4. Enter the duration of the edge
trigger in the Duration (fr) field.
Set up the type of level trigger for the
GPI output.
Devices > GPOGPI Output —
Level Trigger Setup
1. Click GPO Level Config
2. Click the GPO button and select
the GPI output that you want to
configure.
3. Click a Level to select whether
the level trigger uses a high
(High) or low (Low) level trigger.
Select whether the level trigger GPI
output act as a tally.
Devices > GPOGPI Output —
Mode
1. Click GPO Mode
2. Click the GPO button and select
the GPI output that you want to
configure.
3. Click a Mode button to select
whether the level trigger GPI
output, when assigned to video
source, acts as a roll clip
(Normal) or as a tally (Tally) for
the selected source.
Trigger a GPI output.Devices > GPOGPI Output —
Trigger
1. Click GPO Trigger
2. Click the GPO button and select
the GPI output that you want to
trigger.
Select the type of trigger for the GPI
output.
Devices > GPOGPI Output —
Trigger Type
1. Click GPO Trigger
Configuration
2. Click the GPO button and select
the GPI output that you want to
configure.
3. Click a Trigger to select whether
the GPI output uses a level
(Level) or edge (Edge) trigger.
Insert a hold into the custom control.Special > HoldHold CC
Make the selected key linear on the
selected ME, MiniME
™
, or
MultiScreen.
Switcher >
Keyer > Keyer
Make Linear
Key, Make Linear
1. Click the ME button and select
the ME, MiniME
™
, or
MultiScreen that you want to
perform the event on.
2. Click the Keyer button for the
key you want to make linear.
Transition a key (or include it in the
next transition) on or off-air for the
Switcher >
Keyer > Keyer
Active
Key Active
selected ME, MiniME
™
, or
MultiScreen.
1. Click the ME button and select
the ME, MiniME
™
, or
MultiScreen that you want to
perform the event on.
2. Click the Keyer button for the
key you want to perform the
event on.
56 • Custom Controls — Carbonite Black Solo Operation Manual (v1.2)